background image

Contents

1

About this manual......................................  4

1.1

User..................................................... 4

1.2

Other applicable documents................ 4

1.3

Factory settings ................................... 4

1.4

CE mark .............................................. 5

2

Proper use ..................................................  5

2.1

Ultrasonic cleaning .............................. 5

2.2

Misuse ................................................. 5

3

Safety ..........................................................  6

3.1

The structure of warnings.................... 6

3.2

Meaning of symbols on the unit........... 6

3.3

Meaning of symbols on the nameplate

............................................................ 6

3.4

Safety information on specific types of
hazard ................................................. 7

4

Use of cleaning agents ..............................  8

4.1

Permissible cleaning agents................ 8

4.2

Cleaning agents .................................. 8

5

Technical data ..........................................  10

5.1

Elmasonic Select 30–60.................... 10

5.2

Elmasonic Select 80–120.................. 10

5.3

Elmasonic Select 150–300................ 11

5.4

Elmasonic Select 500/900................. 12

5.5

Elmasonic Select 30–900.................. 13

6

Product contents .....................................  14

7

Unit description........................................  15

8

Controls ....................................................  16

8.1

Ultrasound mode display................... 17

8.2

Operating status symbols.................. 17

8.3

Operating modes............................... 18

9

Set up and connect the unit ..................... 18

9.1

Notes on installation site..................... 18

9.2

Set up the unit .................................... 19

9.3

Connect the unit ................................. 19

10 Insert objects to be cleaned ..................... 20

11 Fill the tank ................................................ 20

12 Operating the unit ..................................... 21

12.1 Switch on the unit ............................... 21

12.2 Set the cleaning duration.................... 22

12.3 Set the target temperature.................. 22

12.4 Switch the heating on/off .................... 22

12.5 Set the ultrasound mode .................... 23

12.6 Set auto-degas ................................... 23

12.7 Set Temperature-controlled start........ 23

12.8 Start ultrasonic cleaning ..................... 24

12.9 Save programmes .............................. 24

12.10 Start a saved ultrasonic cleaning

programme ......................................... 25

12.11 Switch off and save ............................ 25

12.12 Remove cleaned objects .................... 26

13 Drain the unit ............................................. 26

14 Change parameters in Setup ................... 27

15 Malfunctions/fault messages ................... 29

15.1 Troubleshooting.................................. 29

15.2 Fault messages .................................. 29

16 Maintenance .............................................. 30

16.1 Replace the network cable ................. 30

16.2 Clean enclosure.................................. 31

16.3 Cleaning the tank................................ 31

16.4 Disinfect.............................................. 31

16.5 Clean the blower, and check that it is

working correctly................................. 31

16.6 LED test.............................................. 32

17 Disposal ..................................................... 32

Elma Schmidbauer GmbH

Contents

Elmasonic Select

iii

Summary of Contents for Elmasonic Select

Page 1: ...04 2021 Translation of the original manual Elmasonic Select Ultrasonic cleaning unit english Version 1 Item No 1112616...

Page 2: ...ts reserved Elma Schmidbauer GmbH Gottlieb Daimler Strasse 17 78224 Singen Germany www elma ultrasonic com Technical Support Tel 49 7731 882 280 Email support elma ultrasonic com Subject to technical...

Page 3: ...unit 18 9 1 Notes on installation site 18 9 2 Set up the unit 19 9 3 Connect the unit 19 10 Insert objects to be cleaned 20 11 Fill the tank 20 12 Operating the unit 21 12 1 Switch on the unit 21 12 2...

Page 4: ...They must have read and understood the manual and be capable of following all notes and instructions All tasks that go beyond the pure operation of the unit within the scope described here must be per...

Page 5: ...Unauthorised persons in particular children must not use this product Only use original accessories made for this product 2 2 Misuse Misuse refers to any use of the unit that deviates from proper use...

Page 6: ...Death or serious injury WARNING Possible dangerous situation Death or serious injury CAUTION Possible dangerous situation Slight injuries damage to components or units NOTICE Useful advice or tip No...

Page 7: ...proved for this unit In case of doubt ask the manufacturer or supplier Infections Danger of possible infection due to poor cleaning results dirty cleaning fluid and insufficient maintenance and disinf...

Page 8: ...women must not be subjected to the noise emissions for longer periods of time Keep animals away from the vicinity of ultrasonic devices Electromagnetic radiation No binding statement can be made for p...

Page 9: ...ration of liquids and form extremely fine mists that readily ignite on contact with sources of ignition This can result in severe burns or death Do not use cleaning agents that are labelled with the p...

Page 10: ...L 1 6 2 9 4 3 Weight unit with cover kg 3 6 3 8 5 2 Performance data Total power consumption W 320 320 550 Effective ultrasonic power 10 W 120 120 150 Peak ultrasonic output max W 480 480 600 Heating...

Page 11: ...s W D H unit with cover mm 575 360 230 405 360 330 575 360 330 Interior dimensions W D tank below fill level marking mm 485 280 300 370 475 270 Fill level tank base to fill level marking mm 65 165 165...

Page 12: ...marking mm 500 330 600 500 Fill level tank base to fill level marking mm 235 200 Working height basket base to fill level marking mm 220 190 Recommended tank operating capacity L 40 3 63 7 Weight uni...

Page 13: ...rget temperature C 80 Degree of protection IP20 Protection class I Ambient conditions Temperature transport C 15 to 60 Temperature operation storage C 5 to 40 Air pressure transport storage hPa 500 1...

Page 14: ...a damaged unit into operation Dispose of packaging materials that are no longer required in an environmentally friendly manner 1 2 3 4 5 6 Illustration 1 Included items schematic diagram 1 Ultrasonic...

Page 15: ...tch open close drain 2 Display splash proof 8 Feet non slip 3 Handle 9 Membrane keyboard wipeable 4 Mains connection 10 Blower on the unit base not shown not available for Elmasonic Select 30 100 5 Na...

Page 16: ...art long press 4 Temperature display value unit symbol 5 Plus minus buttons set temperature programme memory parameter values short press quick cycle long press 6 Select button to switch between progr...

Page 17: ...pulse to improve the overall cleaning power 8 2 Operating status symbols The following symbols are shown on the display as soon as the unit enters the respective operating status End of cleaning Ultr...

Page 18: ...arameters Set operating parameters During Normal mode Current operating status Programme mode The unit is ready to use Four stored programmes can be selected for ultrasonic cleaning The programmes can...

Page 19: ...ts etc on hand Place the unit on the selected surface IMPORTANT The controls such as the display buttons and if applicable discharge tap must be clearly visible and easily accessible The unit has been...

Page 20: ...nded for use in ultrasonic cleaning are water softened water or distilled water Cleaning power can be improved by adding suitable cleaning agents The unit and the tank are clean and if necessary disin...

Page 21: ...ion Pregnant women must not spend long periods of time near an ultrasonic unit in operation Keep animals away from the ultrasonic unit CAUTION Dry running Damage to the tank and unit Always fill the t...

Page 22: ...own to increase decrease the duration more quickly 12 3 Set the target temperature From 25 80 C 77 176 F Press one of the Plus minus buttons below the temperature display to set the required target te...

Page 23: ...controlled start Use this function to start ultrasound operation automatically once the target temperature has been reached IMPORTANT When cleaning sensitive objects please note that the ultrasound i...

Page 24: ...e the current temperature and the set ultrasound mode are continuously shown on the display The ultrasound mode temperature duration and heating On off can be changed during ultrasonic cleaning IMPORT...

Page 25: ...uttons to select a programme Press the Start stop button to start the displayed programme The Remaining time and Heating symbols will be shown on the display if saved The remaining time the current te...

Page 26: ...her ultrasonic cleaning process Switch off the unit If the fluid is dirty or will not be used again empty out the liquid See the section Drain the unit for information 13 Drain the unit CAUTION Hot li...

Page 27: ...chapter Maintenance for information CAUTION Never submerge the unit in water The unit is emptied cleaned and where necessary disinfected 14 Change parameters in Setup IMPORTA NT If parameters marked...

Page 28: ...ff melody 1 melody 2 06 Acoustic signal for Error message 00 01 02 Off melody 1 melody 2 07 Acoustic signal for Temperature limit exceeded 00 01 02 Off melody 1 melody 2 08 Response if temperature lim...

Page 29: ...ltrasonic operation does not start Ultrasonic unit defective Contact the manufacturer Display shows Er Error message Check the error code and rectify the fault contact the manufacturer if necessary Bl...

Page 30: ...after approx one minute The unit has been reset to factory settings The error number displayed is not listed here make a note of the error number the unit must be repaired at the factory IMPORTA NT Em...

Page 31: ...the tank 8 Use a damp cloth to wipe out the remaining limescale and dirt residue If necessary rinse the tank using a shower set CAUTION Do not spray the outside of the unit with water The tank has be...

Page 32: ...if any LED indicators are not displayed The unit has been switched off Hold down the Mode button until the Setup menu is shown on the display To set the LED test function press the Plus minus buttons...

Reviews: