12 Operating the unit
Elma Schmidbauer GmbH
24 / 32
Elmasonic Select
12.8
Start ultrasonic cleaning
The display shows the current settings.
For information on changing the settings, see Set cleaning duration, ultrasound mode and target
temperature.
The described settings have been configured and should be started.
If necessary, press the
Plus
button to heat the cleaning fluid. The
Heating
symbol will be
shown on the display. The display shows the set target temperature and the current
temperature of the cleaning fluid flashing alternately. If necessary, wait until the target
temperature has been reached.
Press the
Start/stop
button to begin ultrasound operation in the displayed mode. The
Remaining time
symbol is shown on the display. The remaining time, the current
temperature and the set ultrasound mode are continuously shown on the display.
The ultrasound mode, temperature, duration and heating
On/off
can be changed during
ultrasonic cleaning.
IMPORTANT
Changing the duration switches off ultrasonic cleaning.
Press the
Start/stop
button to restart ultrasonic cleaning with the altered time setting.
The end of cleaning is indicated by the
End of cleaning
symbol and, where applicable, an
acoustic signal (depending on the parameter settings). The remaining time display will
disappear.
12.9
Save programmes
You can save up to four programmes.
Display in Save mode
Display in Programme mode
1
2
3
1
2
4
To save the currently set programme, use the
Plus/minus buttons to select a programme
number from 1 to 4.
The settings have been configured in Normal mode. These settings can be saved as a programme.
IMPORTANT
The
auto-degas
and
Temperature-controlled start
modes can only be saved separately as
programmes.