EIR600 is an outdoor detector with double passive infrared (PIR) motion sensor which minimises the risk of false alarms caused 
by small animals, cars or other external interferences, making it easy and practical to use. The automatic temperature sensitivity 
adjustment guarantees optimal performance regardless of environmental changes or external interferences. 
Furthermore, the global detection range efficiently adapts to all installation environments. 

 

Component identification 

The detector consists of two parts: cover and base. The cover contains all the electronic and optical parts, while the base is 

used for fixing. The base of the product is provided with holes for installing it on a flat surface or in a corner using the rotating 

shaft provided. 

 

 
 
 
 
 
 
 
 
 

 

 

1.  Test button and LED indicator 

This is the Test button and LED indicator. As Test button, it is used to test radio performance and the system control unit 

learning procedure. As LED indicator, it is used to indicate the system state.  

–  To access Test mode, press the button once in normal mode. The LED lights up for two seconds, independently from 

the detection of a movement. 

2.  Double sensor 
3.  Battery housing  

For two AA 3.6 V lithium batteries.  

 

4.  Tamper switch 

The detector is protected from any attempt to open the cover. 

5.  DIP Switch block 

This contains 8 DIP Switches for setting the function levels and detection sensitivity. 

6.  Bracket arm 
7.  Rotating bracket 

 

LED indicator

 

 

In normal operating mode, the LED indicator blinks to indicate that signals are being transmitted in the following situations. 

 

When movement is detected in flat battery conditions. 

 

When the cover is opened and the tamper switch is actuated. 

 

When movement detected if the tamper alarm condition persists. 

 

When motion is detected in Test mode. 

 

When the Test button is pressed in tampering conditions or if the battery of the device is flat. 

The LED does not blink if the tamper switch is closed, the battery is charged and the detector is not in Test mode. 

The LED blinks to indicate signal transmission, blinking rapidly twice upon receiving confirmation from the panel. 

 

Test mode 

The detector can be set to Test mode for three minutes by pressing the Test button once. In Test mode, the sleep time (see 

below) is off and the LED indicator lights up for two seconds, independently from motion detection. The detector automatically 

exits Test mode after three minutes and goes back to normal mode. 

In order to set the detector to constant Test mode, positioning the DIP Switch 1 the reference to the 

DIP Switch position table

<NOTE> 

The test LED may not be very visible in bright sunlight. In this case, it is advisable to use the Walk Test function, detecting the 

alarms which occurred on the control unit or on the Installer App. 

 

Battery 

 

The detector is powered by two AA 3.6 V lithium batteries. 

 

The detector can detect the low frequency of the batteries. When a flat battery is detected, a flat battery signal is sent to 

the control unit with the normal signal transmission for the control unit to view the corresponding state.  

 

To replace the batteries:

  

 

Front view            Inner view 

 

 

Summary of Contents for EIR600

Page 1: ...T function IR Außendetektor mit PET Funktion Détecteur infrarouge pour extérieur avec fonction PET Manuale d uso installazione e programmazione Installation programming and functions manual Installations programmier und gebrauchsanleitun Notice di installation programmation et utilization I EN DE FR ...

Page 2: ... qualsiasi tentativo di aprire il coperchio 5 Blocco DIP Switch Contiene 8 DIP Switch per impostare i livelli delle funzioni e della sensibilità di rilevamento 6 Braccio della staffa 7 Staffa rotante Indicatore LED In modalità di funzionamento normale l indicatore LED lampeggia per indicare la trasmissione del segnale nelle seguenti situazioni Quando viene rilevato il movimento in condizioni di ba...

Page 3: ...i controllo non ha ricevuto il segnale dal rivelatore per il periodo di tempo preimpostato l unità di controllo segnalerà l allarme di supervisione Sleep Time tempo di riposo Il rivelatore prevede un tempo di riposo automatico di circa un minuto per il risparmio energetico Una volta trasmesso un movimento rilevato il rivelatore non effettuerà una nuova trasmissione per un minuto Qualsiasi ulterior...

Page 4: ...imuovere il coperchio Fase 3 A seconda della preferenza dell utente montare il rivelatore nella posizione desiderata con o senza staffa rotante Montaggio senza staffa rotante La base posteriore del rivelatore è provvista di predisposizioni per i fori dove la plastica è più sottile per consentire il montaggio Due predisposizioni per i fori A servono per il fissaggio su superficie mentre quattro pre...

Page 5: ...nstallazione è completata NOTA NOTA Il rivelatore dispone di un alloggiamento rotante esterno che può essere regolato orizzontalmente pertanto la sua copertura di 110 può variare da 0 a 180 Consigli per l installazione Si consiglia di installare il rivelatore nelle seguenti posizioni 2 3 m misurati dal fondo del dispositivo da terra per ottimizzare le prestazioni In un angolo per avere la visuale ...

Page 6: ...mentre diminuisce se viene montato più in basso di 2 3 m A meno che non sia necessario si consiglia di mantenere la posizione di montaggio del rivelatore all altezza consigliata di 2 3 m per ottimizzare le prestazioni Qualora si modifichi l altezza di montaggio effettuare un test di rilevamento per accertarsi che il rivelatore sia in grado di rilevare normalmente gli intrusi dall altezza desiderat...

Page 7: ...ate that signals are being transmitted in the following situations When movement is detected in flat battery conditions When the cover is opened and the tamper switch is actuated When movement detected if the tamper alarm condition persists When motion is detected in Test mode When the Test button is pressed in tampering conditions or if the battery of the device is flat The LED does not blink if ...

Page 8: ...etector has a double detection function If the double detection function is enabled the detector signals an alarm to the control unit only if two movements are detected in 10 seconds If the double detection function is disabled the detector signals an alarm to the control unit whenever a movement is detected DIP Switch position table The function of each DIP Switch is listed in the following table...

Page 9: ...r four holes in the corner surface 3 Insert the anchor bolts if the device is fixed to plaster or bricks 4 Install the base cover in the anchor bolt with the mounting screws provided 5 Reposition the upper cover on the base and firmly press the upper part until it clicks as shown on the right 6 Tighten the locking screw Mounting with rotating bracket A rotating bracket is provided to allow a flexi...

Page 10: ... heat such as fires or boilers and do not install over radiators Remove all light reflecting surfaces from the detection area as well as water bodies Never attempt to dismantle or modify the unit IMPORTANT NOTE IMPORTANT NOTE Adjust the Dip Switch according to the installation position of the detector to optimise performance If the Dip Switch settings do not corresponds to the installation environ...

Page 11: ...LIFIED EU DECLARATION OF CONFORMITY Hereby URMET S p A declares that the radio equipment type OUTDOOR IR DETECTOR WITH PET FUNCTION EIR600 is in compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address www elkron com ELKRON Tel 39 011 3986711 Fax 39 011 3986703 www elkron com mail to info elkron it ELKRON is a trademark o...

Page 12: ... Für zwei 3 6 V Lithium Batterien Typ AA 4 Tamper Schalter als Sabotageschutz Der Detektor ist vor jeglichen Versuchen des Öffnens der Abdeckung geschützt 5 Dip Switch Block Enthält 8 DIP Switches zur Eingabe der Ebenen der Funktionen und der Empfindlichkeit der Erfassung 6 Ausleger der Halterung 7 Drehhalterung LED Anzeige In der normalen Betriebsart blinkt die LED Anzeige um die Signalübertragun...

Page 13: ...Temperalarm wieder aktivieren Der Vorgang ist abgeschlossen HINWEIS HINWEIS Während des Ersetzens besonders darauf achten die Kontakte des Batteriefachs nicht zu beschädigen Überwachungssignal Nach der Installation überträgt der Detektor automatisch in regelmäßigen Abständen die Überwachungssignale an das Steuergerät Hat das Steuergerät das Signal vom Detektor nicht während der festgelegten Zeit e...

Page 14: ...rstellung der werksseitigen Werte erneut auf einem Steuergerät eingelernt werden müssen alle unter dem vorangegangenen Punkt Anschluss an das System aufgeführten Schritte ausgehend vom Entnehmen der Batterien aus ihrem Fach ausgeführt werden Montage und Installationsmethode Schritt 1 Sobald der Walk Test durchgeführt wurde um zu bestätigen dass der Detektor sich im Abdeckungsbereich befindet die w...

Page 15: ...schützten Bereichs bewegen um sicherzustellen dass der Abdeckungsbereich der Erfassung angemessen ist Bei jeder Bewegungserfassung schaltet sich die LED zur Bestätigung zwei Sekunden lang ein Schritt 5 Wird beschlossen dass die Erfassungsabdeckung zufriedenstellend ist ist die Installation abgeschlossen Schritt 5 Wird beschlossen dass die Erfassungsabdeckung zufriedenstellend ist ist die Installat...

Page 16: ...öhe von mehr als 2 3 m montiert wird während er sich bei einer Montage unter 2 3 m verringert Außer im Fall der Notwendigkeit wird um die Leistungen zu optimieren empfohlen die Montageposition des Detektors auf der empfohlenen Höhe von 2 3 m beizubehalten Sollte die Montagehöhe verändert werden einen Erfassungstest ausführen um sich zu vergewissern dass der Detektor in der Lage ist Eindringlinge a...

Page 17: ...clignote pour indiquer la transmission du signal dans les situations suivantes Quand le mouvement est détecté avec batterie épuisée Quand le couvercle est ouvert et l interrupteur tamper est activé Quand un mouvement est détecté si la condition de sabotage persiste Quand un mouvement est détecté en mode Test Quand on appuie sur la touche Test dans des conditions de sabotage ou si la batterie du di...

Page 18: ...uvercle Selon les besoins configurer l interrupteur de sensibilité comme illustré dans la Table des positions des DIP Switch Insérer deux batteries au lithium AA 3 6 V dans le logement des batteries respectant la polarité La LED clignotera pendant 30 secondes Le détecteur est en phase d initialisation Pendant l initialisation le détecteur n est pas activé Il est conseillé de ne pas déclencher d al...

Page 19: ...es si l installation est effectuée dans du plâtre ou des briques 4 Installer la couverture de la base dans les chevilles avec la vis de montage fournie 5 Mettre le couvercle sur la base et enfoncer jusqu au déclic comme illustré à droite 6 Serrer la vis de blocage Montage avec étrier pivotant Un étrier pivotant est fourni avec le dispositif pour rendre l installation plus flexible L étrier pivotan...

Page 20: ...intrus qui traversent la zone de détection Il est moins sensible pour les mouvements dirigés vers le détecteur Pour optimiser les performances ajuster la hauteur d installation du détecteur en fonction de la taille de l animal le plus grand de la maison Dans le cas de chiens de taille supérieure à la moyenne monter le détecteur plus haut Si installé à une hauteur de 2 3 m sous le détecteur il y a ...

Reviews: