  Installation Step 4: System Programming 

 

Programming Horizontal Limits & Stow Position 

The 8593-04 Copperhead RF monitor must show H2 limits relative to mounting 
flange. The monitor is shipped from the factory with horizontal limits at 180° (90° 
left and 90° right of the straight ahead position). The vertical limits are provided by 
magnets placed in the monitor at assembly and are not adjustable. 

 

NOTE: All programming steps must be completed. Otherwise the changes will not be 
stored to permanent memory. 

  Remove the cover from the RF Receiver/Control Module located on the monitor. 

  Supply power to the monitor. 

  Hold the Red Programming Button on the control module board until the programming LED 

flashes on (approx. 5 seconds). 

  To set the left travel limit, rotate the monitor left until it has reached the mechanical stop. 

Quickly press and release the Red Programming Button. The status LED will flash once to 
acknowledge the new limit position. 

  To set the right travel limit, rotate the monitor right until it has reached the mechanical stop. 

Quickly press and release the Red Programming Button. The status LED will flash twice to 
acknowledge the new limit position. 

  To set the horizontal stow position of the monitor, move the monitor left or right to the desired 

position. Quickly press and release the Red Programming Button. The status LED will flash 
rapidly several times to acknowledge the new stow position. 

NOTE: The stow position must be 

between the right and left limits that were just programmed in the previous two steps. It is not 
recommended to set the position right at the maximum right or left travel limit. 

  To choose the vertical stow position of the monitor, set switch A position 1 “ON” for stow up, or 

switch A position 1 “OFF” for stow down 

(Receiver only). NOTE: The vertical stow position will 

either be all the way up or all the way down, nowhere in between. 

  Remove power from the monitor for a minimum of 5 seconds. Reapply power and operate the 

monitor to verify that the travel limits are at the correct positions, and the monitor stows 
correctly. If not, follow the steps above to reprogram the limits. 

 
 

Red Programming 
Button (SW1) 

Programming 
Status LED (DS5) 

 
 
 

 

 

 
 
 

 

Figure 3: SW1 Programming Button 

 
 

 

 

 

Caution: 

To prevent damage to the monitor controller, keep all metallic objects away 

from the receiver circuit board while it is energized. Ensure all O-rings and gaskets are 
properly installed when closing receiver enclosure. 

Summary of Contents for Copperhead RF 8593-04

Page 1: ...2 8593 04 Monitor Installation Operating Maintenance Instructions 98520000 REV A 1 574 295 8330 www elkhartbrass com...

Page 2: ...lation Step 2 Communication Address Setup 10 Installation Step 3 RFSettingsSetup 11 Installation Step 4 System Programming 13 OPERATING INSTRUCTIONS 14 MAINTENANCE INSTRUCTIONS 16 SYSTEM SPECIFICATION...

Page 3: ...equipment should be operated from a remote location Do not needlessly expose personnel to dangerous fire conditions Open water valves supplying this equipment slowly so that piping fills slowly thus...

Page 4: ...ptional SM 1250BE Electronically Actuated Nozzle 282 B Stream Shaper 2 5 NHT Discharge Fully Vaned Cast Brass Waterway Dual Handwheel Manual Override Sealed High Torque Gearmotor 3 150 ANSI Flange 859...

Page 5: ...n All monitor motors are 12VDC If using a non Elkhart nozzle another 12VDC nozzle should be used or nozzle control may not function properly NOZZLE Copperhead RF Nozzles There are two nozzles recommen...

Page 6: ...equiring no wires between the RF transmitter and the monitor It is powered by the vehicle electrical system The faceplate is intended for a flush mount onto the pump panel Separate sealed push button...

Page 7: ...ace mount type switch box with controls for operation of the monitor for use with the OEM secondary RF transmitter Separate sealed toggle switches are furnished for up down left right and strt fog fun...

Page 8: ...Alignment is correct when the straight ahead position is centered between adjacent flange holes Attach monitor inlet flange to companion flange on water supply pipe with four 4 2 5 8 11 UNC grade 5 s...

Page 9: ...rtment and in a position that provides the least obstructed line of sight to the monitor s antenna Place a 1A fuse between the red lead of the RF controller and a switched positive power lead on the v...

Page 10: ...to a relay or LED supplied by the OEM The circuit switches in a ground and is limited to 250 mA of current when the monitor is in a non stowed position Installation Step 2 Communication Address An RF...

Page 11: ...and milled slot in the base Follow the programming steps to set all travel limits as prescribed in Installation Step 4 NOTE The horizontal limits must be set to stop the motors at the location of the...

Page 12: ...Programming Button The status LED will flash twice to acknowledge the new limit position To set the horizontal stow position of the monitor move the monitor left or right to the desired position Quick...

Page 13: ...ttons are pressed at the same time the monitor will stop all motion To continue motion release both buttons and repress the desired direction button This is also true for the up down and fog stream co...

Page 14: ...ts Serious damage to motor gear heads will occur Storing the Monitor Elkhart Brass recommends that a stow position be set and the stow routine be utilized to place the monitor in its stowed position a...

Page 15: ...r is exposed to a high level of radiant heat for a prolonged period it may be possible for the factory grease to thin and run out of the rotation joints In such an event fresh grease should be applied...

Page 16: ...Lithium batteries Replace the battery cover DS4 DS2 DS3 DS6 SW1 DS1 SW3 DS5 SW4 B P4 P1 P3 P2 A SW2 Reference Indication Meaning 1 Light comes on for 1 second when monitor stops Motor has reached stal...

Page 17: ...nts Without Converter Assembly 12VDC 11 14VDC WithConverter Assembly 11 30VDC at the controller under full load Electrical Load See Table 4 Below Control current 0 07 A 12V Operatingtemperaturerange 4...

Page 18: ...CHECK BEFORE DRILLING NOTE Pages must NOT be scaled during printing or template size will be scaled incorrectly Panel Mount Controller Mounting Template COMPONENT MOUNTING TEMPLATES IF YOU CAN SEE THI...

Page 19: ...ROM THE DIGITAL PDF DOUBLE CHECK BEFORE DRILLING Secondary Control Switch Box Mounting Template 0 24 2 HLS REQ D 4 92 4 45 0 281 DRILL THRU IF YOU CAN SEE THIS TEXT PLEASE REPRINT THIS PAGE AT 100 NOT...

Page 20: ...21 Auxiliary Battery Mounting Layout THIS IS NOT A TEMPLATE...

Page 21: ...DSLEY AVE P O BOX 1127 ELKHART IN 46514 PHONE 1 574 295 8330 1 800 346 0250 FAX 574 293 9914 WWW ELKHARTBRASS COM ELKHART BRASS MFG CO INC 2014 8593 04 MONITORS INSTALLATION OPERATION AND MAINTENANCE...

Reviews: