VERIFY CONTROL BOARD  SOFTWARE

1) To verify the software program of the control board the unit will  

    need to be shut down and restarted. The chiller (if present) does 

    not need to be shut down and restarted.

2) The units lower panel must be open to access the power cord and 

    wall outlet.

3) Shut down the unit by unplugging the power cord from the wall 

    outlet or switching off the circuit breaker to the unit.  

4) Restart the unit by plugging the power cord back into the wall 

    outlet or by switching on the circuit breaker to the unit.

5) Upon start up, the bottle count display will show the software 

     designation of BF11 or BF12.

ACCESSING THE PROGRAMMING BUTTON

1)   To access the program button, open the lower panel. Reset button  

  is located at the lower right hand side of the top panel.

RESET THE FILTER MONITOR

1) Instructions apply to filtered units only.

2) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Monitor

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

3) When the display changes to “RST FLTR”, depress the button 

    again. The display will change to show “FLTR =”. Depress the

    button again and the display will show “FLTR =0”

4) The Green LED should be illuminated indicating that the visual 

    filter monitor has been reset.

 SETTING RANGE OF THE IR SENSOR

1) Depress the program button for approximately 2 seconds until 

    the display changes then release. The display will change and 

    scroll through two messages:

       “RST FLTR” – Reset Filter Status LED

     “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

2) When the display changes to “SETTINGS”, depress the button 

    again. The display will change to show

      “RNG SET” -  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

      “FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

3)  When display shows “RNG SET” push program button once the 

    display will show current value (can be 1 – 10) e.g. “RNG = 3”.

4) Once display shows current value push the program button to 

    scroll through value of 1 – 10. Select the desired range setting, 

  "1" being closest to sensor and "10" being farthest away.

5) Once range is selected allow approximately 4 seconds to pass and

    then the display will go back to bottle counter and be in run mode.

6)  Test bottle filler by placing bottle or hand in front of sensor to 

    make sure water is dispensed.

SETTING UNIT TYPE

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll 

    through two messages:

       “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll 

    through the two messages above for three cycles and then default 

    back to bottle count and be back in run mode.

Continued from below:

2)  When the display changes to “SETTINGS”, depress the button again.  

      The display will change to show

       “RNG SET” -  Range set for IR sensor.

       “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       “FLT SIZE” - Select filter capacity

       “RST BCNT” - Reset bottle count

3)  When display shows “UNIT TYPE” push program button once the

    display will show current value.  Can be REFRIG or NON-RFRG

4) Push button once to change value. Once value is    selected the display 

    will show the new value.  (Can be REFRIG or NON-RFRG)  

     

“REFRIG“ - stands for refrigerated product. In this setting the flow rate is 

    estimated at 1.0 gallon per minute.

     “NON-RFRG“ - stands for nonrefrigerated product. In this setting the  

    flow rate is estimated at 1.5 gallons per minute.  Both “REFRIG“ and 

    “NON-RFRG“ simulate   1 bottle equal to 20 oz.

5) 

 Allow approximately 4 seconds to pass and the display will return to    

    bottle counter and be in run mode.

    

 RESETTING BOTTLE COUNT

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll

    through two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through  

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET”-  Range set for IR sensor.

      “UNIT TYP” - Type of unit (REFRIG or NON-RFRG)

       

“FLT SIZE” - Select filter capacity

      “RST BCNT” - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  When display shows “RST BCNT” push program button once the

    display will show current value, e.g. “0033183”.

4) Once display shows current value push the program button once more 

    to reset back to 0. The display will show BTLCT = 0 for approximately 2 

    seconds and then return to run mode showing 00000000 bottles. 

 

NOTE: Once the bottle count is reset to zero there is no way to 

  return to the previous bottle count.

5) 

 Testing the bottle counter:

     REFRIG units: Place bottle or hand in front of sensor for approximately 

  9 seconds to see bottle counter count 00000001, 

     (This is based on filling a 20 oz. bottle).

     NON-RFRG units: Place bottle or hand in front of sensor for 

  approximately 6 seconds to see bottle counter count 00000001,

     (This is based on filling a 20 oz bottle).

    

 SETTING FILTER CAPACITY

1) Depress the program button for approximately 2 seconds until the

    display changes then release. The display will change and scroll through 

    two messages:

      “RST FLTR” – Reset Filter Status LED

      “SETTINGS” – System Settings Sub Menu

    If the program button is not pushed again the display will scroll through 

    the two messages above for three cycles and then default back to bottle 

    count and be back in run mode.

2)  When the display changes to “SETTINGS”, depress the button again. 

     The display will change to show:

      “RNG SET“-  Range set for IR sensor.

      “UNIT TYP“ - Type of unit (REFRIG or NON-RFRG)

      

 “FLT SIZE” - Select filter capacity

      “RST BCNT“ - Reset bottle count

    If the button is not pushed again the display will scroll through the four 

    messages above for three cycles and return to run mode.

3)  When display shows “FLT SIZE” push program button once. The display 

     will show current value. Can be 3000GAL or 6000GAL.

4)  Push program button again to display the desired “FLT SIZE”. 

5)  Allow approximately 4 seconds to pass and the display will return to 

     bottle counter and be in run mode.

BF11 - BF12 PROGRAM

SETTING THE CONTROL BOARD

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oakpark Dr., Unit A, Mooresville, NC 28115

Summary of Contents for ezH2O EZWSM8 Series

Page 1: ...ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO E...

Page 2: ...OTHERS BACK WALL LINE 8 203MM MINIMUM FOR DRAIN CONNECTION AND ACCESS TO BOTTLE FILLER ELECTRICALS FINISHED FLOOR 25 1 4 642mm 27 682mm 2 7 8 73mm 25 7 8 657mm 1 1 4 32MM WASTE TUBE FURNISHED 3 1 2 89...

Page 3: ...657mm 1 1 4 32MM WASTE TUBE FURNISHED 3 1 2 89mm 4 1 2 117mm 1 1 8 29mm 11 279mm ELECTRICAL INLET FINISHED FLOOR 17 3 8 441mm 1 3 16 30mm 1 3 16 30mm 19 3 4 502mm 21 15 16 557mm 38 7 8 988mm 18 7 8 48...

Page 4: ...LLATION Fig 6 Filter units only For non filtered units proceed to step 15 NOTICE Do not use water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after t...

Page 5: ...minimum space of 4 102mm on top sides and a depth of 12 305mm 20 Remove Chiller Front panel Remove the 10 screws securing chiller front panel 21 Connect electrical to chiller Make sure power supply i...

Page 6: ...icating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR 1 Depress the program button for approximately 2 seconds until the display changes then release The display will ch...

Page 7: ...be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button for approximately 2 seconds until the d...

Page 8: ...o show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display shows UNIT TYPE push program button once the...

Page 9: ...S 1 800 260 6640 DESCRIPTION 98543C 98544C 98545C 98546C 98549C 98631C 98632C Kit Electrical Package Kit EE Sensor Kit Solenoid Valve Replacement Kit Aerator Replacement Kit Hardware Waterway Parts Ki...

Reviews: