EZWSMD*1A EZWSM8*1A EZWSM8*2A LZWSMD*1A LZWSM8*1A LZWSM8*2A
Page 6
98557C (Rev. R - 11/20)
BF6-BF7-BF8 PROGRAMS
SETTING THE CONTROL BOARD
VERIFY CONTROL BOARD SOFTWARE
1) To verify the software program of the control board the
unit will need to be shut down and restarted. The chiller
(if present) does not need to be shut down and restarted.
2) The units lower panel must be open to access the power
cord and wall outlet.
3) Shut down the unit by unplugging the power cord from the
wall outlet.
4) Restart the unit by plugging the power cord back into the
wall outlet.
5) Upon start up the bottle count display will show the
software designation of BF6, BF7, BF8, BF9 or BF11.
6) Reference the BF6-BF7-BF8-BF9 or BF11 instructions for
setting the control board.
ACCESSING THE PROGRAMMING BUTTON
1) To access the program button the lower panel of the
unit must be must be opened. The programming button is
located at the bottom right corner of the upper panel.
This area of the unit is concealed by the lower panel.
RESET THE FILTER MONITOR
1) Instructions apply to filtered units only.
2) Depress the program button for approximately 2 seconds
until the display changes then release. The display will
change and scroll through three messages:
“RST FLTR”
– Reset Filter Status LED
“RST BCNT”
– Reset Bottle Count
“RNG SET”
– Range Set for IR Sensor
If the program button is not pushed again the display
will scroll through the three messages above for
three cycles and then default back to bottle count and
be back in run mode.
3) When the display changes to "RST FLTR", depress
the button again. The display will change to show
"FLT=". Depress the button again and the display will
show "FLTR=0".
4) The green LED should now be illuminated indicating
that the visual filter monitor has been reset.
SETTING RANGE OF THE IR SENSOR
1) Depress the program button for approximately 2 seconds
until the display changes then release. The display will
change and scroll through three messages:
“RST FLTR”
– Reset Filter Status LED
“RST BCNT”
– Reset Bottle Count
“RNG SET”
– Range Set for IR Sensor
2) If the program button is not pushed again the display
will scroll through the two messages above for
three cycles and then default back to bottle count
and be back in run mode.
3) When display shows “RNG SET” push program button
once the display will show current value
(can be 1 – 10) e.g.
“RNG = 3”
.
4) Once display shows current value push the program
button to scroll through value of 1 – 10. Select the
desired range setting.
5) Once range is selected allow approximately 4 seconds
to pass and then the display will go back to bottle counter
and be in run mode.
6) Test bottle filler by placing bottle or hand in front of
sensor to make sure water is dispensed.
RESETTING BOTTLE COUNT
1) Depress the program button for approximately 2 seconds
until the display changes then release. The display will
change and scroll through two messages:
“RST FLTR”
– Reset Filter Status LED
“RST BCNT”
– Reset Bottle Count
“RNG SET”
– Range Set for IR Sensor
If the program button is not pushed again the display
will scroll through the two messages above for
three cycles and then default back to bottle count
and be back in run mode.
2)
When the display changes to "RST BCNT", depress the
button again. The display will change to show current
bottle count value e.g. "00033183".
3) Depress the button again and the display will change to
"BTLCT=0" for approximately 2 seconds and then return
to run mode displaying 00000000.
4) You can test the bottle counter by running water
approximately 5 seconds to see bottle counter advance 1.
WWW.RESTROOMDIRECT.COM 704•937•2673 129 Oakpark Dr., Unit A, Mooresville, NC 28115