background image

EZWSMD*1A     EZWSM8*1A     EZWSM8*2A     LZWSMD*1A     LZWSM8*1A     LZWSM8*2A

Page 4

98557C (Rev. R - 11/20)

INSTALLATION INSTRUCTIONS

1.  Install 

mounting frame and chiller shelf.  See mounting frame instructions.

2.  Mount the upper BF panel to the mounting frame: 

Mount upper panel by aligning holes in the hinge brackets with holes in the mounting frame 

(three places). Mount with adequate size screws (not provided). Close the door and verify that the lock brackets on the side and bottom of the 

panel align with the slots on the mounting frame.  Also verify that the panel is hanging high enough that it covers the top of the mounting frame. 

3.  Mount the lower Chiller panel to the mounting frame

: Mount the lower panel by aligning holes in the hinge brackets with holes in the mounting 

frame (three places). Mount with adequate size screws (not provided). Close the door and verify that the lock brackets on the side of the panel 

align with the slots on the mounting frame.  If adjustments need to be made, open the doors to make adjustments. Open panels for adjustments. 

Loosen the (4) screws on the hinges of each panel and adjust accordingly and then re-tighten screws. Close and Lock the top panel in place 

using two set screws (provided) on the side of the panel, and a ¼ x 20 bolt through the front of the panel into the nut in the frame. 

4.  Attach drain: 

Attach the drain fittings to drain tube. Attach elbow to p-trap and cut waste tube to required length using plumbing hardware and 

trap as a guide.

5.  Install remote chiller:

 See chiller instructions. Remove protective caps from water lines on chiller.

TO BOTTLE FILLER

CHILLER

INLET

PLUMBING DIAGRAM

Fig. 6

EWF3000 WATERSENTRY PLUS FILTER INSTALLATION

 (Fig. 6): (Filter units only. For non-filtered units proceed to step 15)

NOTICE

: Do not use water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

CAUTION

: If supply pressure will ever exceed 100 psi, install a pressure regulator set to 100 psi or below.

DO NOT ATTACH HOT WATER LINE TO FILTER HEAD.

Filter kits must be installed in compliance with all state and local laws and regulations governing the installation and use of this product. 
Maximum inlet water temperature: 100°F (38°C).

See filter instructions for filter head assembly.

6.  Connect Filter Kit: 

Using the filter mounting bracket and screws supplied, mount filter head using the (3) screw holes on the side of the chiller. 

Allow enough room under the filter head for the installation and removal of the filter cartridge (13” minimum). To make tube connections on the 

filter head, loosen locknut. Push the tube end past both O-rings to a positive stop in the filter head recess - approx. 1".  Screw the locknut hand 

tight to seal (See Fig. 5). Ends of tubing must be cut square and free of burrs and sharp ends that could cut or nick the O-rings.

7.  Connect filter water outlet: 

Connect the outlet of the filter head to the inlet of the chiller using the ¼” O.D. poly tubing and ¼” elbow  

 

union supplied.

8.  Place Chiller on Shelf: 

When mounting unit in a cavity or behind a wall maintain a minimum space of 4” (102mm) on top, sides and a  

 

depth of 12” (305mm).

9.  Connect bottle filter line:

 Connect water line from BF station by inserting the ¼” O.D. poly tubing into union on the chiller outlet.

10. Remove Chiller Front panel: 

Remove the (10) screws securing chiller front panel.

NOTE: SCREW THE LOCK-

NUT HAND TIGHT TO SEAL

Fig. 5

FILTER

CHILLER

TO BOTTLE FILLER

INLET

STRAINER

NON FILTERED

FILTERED

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oakpark Dr., Unit A, Mooresville, NC 28115

Summary of Contents for ezH2O EZWSM8 Series

Page 1: ...ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO E...

Page 2: ...OTHERS BACK WALL LINE 8 203MM MINIMUM FOR DRAIN CONNECTION AND ACCESS TO BOTTLE FILLER ELECTRICALS FINISHED FLOOR 25 1 4 642mm 27 682mm 2 7 8 73mm 25 7 8 657mm 1 1 4 32MM WASTE TUBE FURNISHED 3 1 2 89...

Page 3: ...657mm 1 1 4 32MM WASTE TUBE FURNISHED 3 1 2 89mm 4 1 2 117mm 1 1 8 29mm 11 279mm ELECTRICAL INLET FINISHED FLOOR 17 3 8 441mm 1 3 16 30mm 1 3 16 30mm 19 3 4 502mm 21 15 16 557mm 38 7 8 988mm 18 7 8 48...

Page 4: ...LLATION Fig 6 Filter units only For non filtered units proceed to step 15 NOTICE Do not use water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after t...

Page 5: ...minimum space of 4 102mm on top sides and a depth of 12 305mm 20 Remove Chiller Front panel Remove the 10 screws securing chiller front panel 21 Connect electrical to chiller Make sure power supply i...

Page 6: ...icating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR 1 Depress the program button for approximately 2 seconds until the display changes then release The display will ch...

Page 7: ...be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button for approximately 2 seconds until the d...

Page 8: ...o show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display shows UNIT TYPE push program button once the...

Page 9: ...S 1 800 260 6640 DESCRIPTION 98543C 98544C 98545C 98546C 98549C 98631C 98632C Kit Electrical Package Kit EE Sensor Kit Solenoid Valve Replacement Kit Aerator Replacement Kit Hardware Waterway Parts Ki...

Reviews: