LZWSM8*, LZWSMD* EZWSM8*, EZWSMD* ROUGH-IN

Fig. 3

20 3/8"

518mm

20 7/16"

519mm

19 3/4"

502mm

17 3/8"

441mm

1 3/16"

30mm

1 3/16"

30mm

8 1/8"

206mm

9 3/8"

238mm

1 1/8"

29mm

3"

79mm

18 3/4"

476mm

4"

102mm

FILTER LOCATION

1/4" O.D. TUBE CONNECT

(CHILLER WATER OUTLET)

3/8" O.D. TUBE CONNECT

(CHILLER WATER INLET)

SHUT OFF VALVE BY OTHERS

BACK WALL LINE

8" 203MM MINIMUM

FOR DRAIN CONNECTION

AND ACCESS TO

BOTTLE FILLER

ELECTRICALS

FINISHED FLOOR

25 1/4"

642mm

27"

682mm

2 7/8"

73mm

25 7/8"

657mm

1-1/4" (32MM)

WASTE TUBE

FURNISHED

3 1/2"

89mm

4 1/2"

117mm

1 1/8"

29mm

11"

279mm

ELECTRICAL

INLET

FINISHED FLOOR

DOUBLE STUD OR 3" (76mm)

BETWEEN MOUNTING FRAMES

IF PLACED NEXT TO ANOTHER

FOUNTAIN OR WALL

32 11/16"

831mm

ACTIVATION 

  SENSOR

38 7/8

987mm

NOTE: NON-REFRIGERATED

MODELS (WITHOUT CHILLER)

DO NOT INCLUDE LOUVERS

JUNCTION BOX

LOCATION

27 3/8"

693.74MM

WWW.RESTROOMDIRECT.COM      704•937•2673     129 Oakpark Dr., Unit A, Mooresville, NC 28115

Summary of Contents for ezH2O EZWSM8 Series

Page 1: ...ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO E...

Page 2: ...OTHERS BACK WALL LINE 8 203MM MINIMUM FOR DRAIN CONNECTION AND ACCESS TO BOTTLE FILLER ELECTRICALS FINISHED FLOOR 25 1 4 642mm 27 682mm 2 7 8 73mm 25 7 8 657mm 1 1 4 32MM WASTE TUBE FURNISHED 3 1 2 89...

Page 3: ...657mm 1 1 4 32MM WASTE TUBE FURNISHED 3 1 2 89mm 4 1 2 117mm 1 1 8 29mm 11 279mm ELECTRICAL INLET FINISHED FLOOR 17 3 8 441mm 1 3 16 30mm 1 3 16 30mm 19 3 4 502mm 21 15 16 557mm 38 7 8 988mm 18 7 8 48...

Page 4: ...LLATION Fig 6 Filter units only For non filtered units proceed to step 15 NOTICE Do not use water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after t...

Page 5: ...minimum space of 4 102mm on top sides and a depth of 12 305mm 20 Remove Chiller Front panel Remove the 10 screws securing chiller front panel 21 Connect electrical to chiller Make sure power supply i...

Page 6: ...icating that the visual filter monitor has been reset SETTING RANGE OF THE IR SENSOR 1 Depress the program button for approximately 2 seconds until the display changes then release The display will ch...

Page 7: ...be in run mode 6 Test bottle filler by placing bottle or hand in front of sensor to make sure water is dispensed SETTING UNIT TYPE 1 Depress the program button for approximately 2 seconds until the d...

Page 8: ...o show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When display shows UNIT TYPE push program button once the...

Page 9: ...S 1 800 260 6640 DESCRIPTION 98543C 98544C 98545C 98546C 98549C 98631C 98632C Kit Electrical Package Kit EE Sensor Kit Solenoid Valve Replacement Kit Aerator Replacement Kit Hardware Waterway Parts Ki...

Reviews: