11. Connect electrical to chiller:
Make sure power supply is identical in voltage, cycle and phase to that specified on cooler serial plate. Never wire
Compressor directly to the power supply. While chiller panel is off, adjust cold control if needed.
12. Replace chiller panel:
Using the (10) screws re-secure the panel.
13. Plug bottle filler into wall box receptacle.
14. Install a shut-off valve:
Install a shut-off valve and union connection to building water supply (valve and union not provided). Connect 3/8”
shut-off valve to 3/8” copper tubing inlet of filter head.
15. Install filter cartridge:
remove filter from carton, remove protective cap, and attach filter to filter head by firmly inserting into head and rotating
filter clockwise.
16. Go to step 18.
EWF3000 WATERSENTRY STRAINER INSTALLATION (Fig. 6):
17. For non-filtered units:
Install a shut-off valve and union connection to building water supply (valve and union not provided). Turn on the water
supply and flush the line thoroughly. Turn off water supply. Install the in-line strainer between the valve and the chiller. The in-line strainer is not
installed on filtered units.
18. Connect water supply line:
Connect 3/8” shut-off valve to 3/8” copper tubing to inlet of strainer. Connect water line from BF station by inserting
the ¼” O.D. poly tubing into union on the chiller outlet. Turn on water supply and check for leaks.
19. Place Chiller on Shelf:
When mounting unit in a cavity or behind a wall maintain a minimum space of 4” (102mm) on top, sides and a depth of
12” (305mm).
20. Remove Chiller Front panel:
Remove the (10) screws securing chiller front panel.
21. Connect electrical to chiller:
Make sure power supply is identical in voltage, cycle and phase to that specified on cooler serial plate. Never wire
Compressor directly to the power supply. While chiller panel is off, adjust cold control if needed. Replace chiller panel: Using the (10) screws
re-secure the panel.
22. Turn on water supply:
Turn on the water supply, plug unit into wall (power cord not supplied on 220V models) and activate the electronic eye
on in-wall bottle filler until approximately 1 gallon of water is dispensed. Be sure to reinstall fuse to the circuit or switch the circuit breaker back
to the “ON” position. Once power is applied to Bottle Filler, the GREEN LED LIGHT and/or LCD Bottle Counter should illuminate, the green light
showing good filter status Please. note that the electric eye activation times out at 20 seconds and will need to be activated repeatedly until 1
gallon has been passed. This flushing procedure purges air and fine carbon particles from filter and strainer. When 1 gallon of water has been
purged through the bottle filler, carefully inspect all water connections for leaks.
23. Verify
proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses.
24. Close
and lock the lower panel in place using two set screws (provided) on the side of the panel.
25. Installation Complete.