TROUBLESHOOTING

Nothing Operates

Main Breaker is Off - Set to On.
Sub-Panel Breaker Off - Set to On.
Equipment GFCI Off - Set to On.
Power switch in Off position - Set to On
Over or High Temperature Protection On - Refer to Error Identification  (High Temperature)

System Fuse Indicator Illuminated

Replace system fuse
If power to electrical pack is OK (check L1 & L2 power using power test switch) - Replace circuit board or pack

No, Low Or Surging Water Flow

Air Lock in Plumbing System - “Bleed” the system.
Restricted Flow - Insure that the water slide valves are open and that suction fittings are not blocked by debris.
Dirty Filter - Clean or replace filters.
Low Water Level - Increase water level to recommended level.

No Circulation Pump

Water temperature is 4 degrees above set point - Remove spa cover.  If the water temperature cools down 1 degree above set point the 
circulation pump resumes operation.
Circulation pump blue cord lighted and water temperature is ok.  Replace circulation pump or circ. pump blue cord.
Circulation pump blue cord not lighted and water temperature is ok.  Replace electrical pack.

No Pump 1

Pump 1 cord not plugged into receptacle - Plug pump 1 into red receptacle.
Pump 1 fuse indicator illuminated - Replace Pump 1 fuse and resume normal operation.
Pump 1 red plug not lighted - Replace Circuit board.
Pump 1 red plug lighted - Replace Pump 1 or Pump 1 cord.

No Pump 2

Pump 2 cord not plugged into receptacle - Plug pump 2 into pink receptacle.
Aux. fuse indicator illuminated - Replace Aux. fuse and resume normal operation.
Pump 2 pink plug not lighted - Replace Circuit board.
Pump 2 pink plug lighted - Replace Pump 2 or Pump 2 cord.

No Air Blower Operation

Blower cord not plugged into receptacle - Plug Blower into purple receptacle
Aux. fuse indicator illuminated - Replace Aux. fuse.
Blower purple plug not lit - Replace Circuit Board.
Blower purple plug lit - Replace blower or blower cord.

No Therapy Jet Operation

Jets Not Properly Adjusted - Adjust Jets properly.
Thermal Overload Tripping - Check for restricted flow of water.
Over or High Temperature error - Off-On power to reset.

Water Leaks

Spa Overfilled - Adjust water level.
Too Many People in the Spa - Adjust water level.
Drain-Valve Left Open - Close drain valve.
Couplings or Unions Loose - Tighten or contact your local dealer, or manufacturer.
Plumbing / Connections Leaking - Contact manufacturer.
Water in Air Blower Plumbing - Contact manufacturer.

11

Summary of Contents for Platinum I

Page 1: ......

Page 2: ...Diagram Wiring Diagram Specifications Drawing Electrical Wiring Instructions Start Up Instructions Operating Instructions Error Identification Troubleshooting Spa Care and Maintenance Water Quality an...

Page 3: ...call manufacturer WARNING This manual was written to ensure the proper use and installation your spa Any modifications to the procedures outlined in this manual may result in your warranty being void...

Page 4: ...spa may be installed within 5 feet 1 5m of metal surfaces if each metal surface is permanently connected by a minimum No 8 AWG 8 4mm2 solid copper conductor to the wire connector on the terminal box...

Page 5: ...s It is strongly recommended that a qualified licenced contractor prepare foundation for your spa Manufacturer recommends a poured reinforced concrete slab with a minimum thickness of 4 inches 10cm Wo...

Page 6: ...n Box Ground Green To Spa Ground Bar Attached To Box Green Input Out From House To Box Red Input From House To Box Black Input Load Neutral Bar From House To Box Neutral White Input Ground Green Input...

Page 7: ...cification listed may result in damage to equipment and may void the warranty IF THE SPA IS WIRED INCORRECTLY YOUR WARRANTY WILLBE VOID ON ANY BURNED OUT ELECTRICAL EQUIPMENT G F C I Ground Fault Circ...

Page 8: ...h wires as shown in figure 2 to proper connectors Red L2 White N Green GR Black L1 Conector Pressure Switch Fuses SC 25 Fig 4 Panel Screws Pump 1 Pump 2 Air Jets Ozone Aux Heater Indicator Light CONTR...

Page 9: ...WIRING DIAGRAM 5a...

Page 10: ...SPEC SHEET 5b...

Page 11: ...ct to spa 4 The electrical supply for this product must include a suitably rated circuit breaker to open all ungrounded supply conductors to comply with Section 422 20 of the National Electrical Code...

Page 12: ...volume of water so adjust water level to number of people who will be entering spa If your water is extremely hard it is preferable to fill half way with hard water and the rest of the way with soften...

Page 13: ...the side of the spa as show above Figure 8 The main control panel controls all of the spa functions and uses indicator lights and an integrated LED display to aid in determining the status of the spa...

Page 14: ...ure keys to setAC frequency 1 2 or 3 times a day To save the data press the Jets 1 Key within 5 seconds after adjustment If the Jets 1 Key is pressed second time with in 5 seconds after adjustment the...

Page 15: ...ated If 3 flashing dots appear below the temperature display while the pump s is operating turn the pump s off If the 3 flashing dots went away this indicates that the pressure or flow switch was not...

Page 16: ...Pump 1 Pump 1 cord not plugged into receptacle Plug pump 1 into red receptacle Pump 1 fuse indicator illuminated Replace Pump 1 fuse and resume normal operation Pump 1 red plug not lighted Replace Cir...

Page 17: ...l Storm Power Surge Extremely Humid Conditions or Radio Frequency Interference Reset GFCI NOTE GFCI must be properly grounded and bonded GFCI Trips Immediately Defective Component Contact a qualified...

Page 18: ...hased by phone 1 800 749 8003 Part 6136 Filter Elements Care Of The Exterior Spa Shell Your spa shell is made of acrylic Stains and dirt generally will not adhere to the surface Using a soft rag or a...

Page 19: ...riods 5 to 14 days 0 Set temperature to its lowest level approximate water temperature of 80 F Adjust the pH Sanitize the water Lock cover for safety Return Procedures Sanitize the water following sho...

Page 20: ...used correctly they can be hazardous in concentrated form Observe the following guidelines Allow only a responsible person to handle spa chemicals KEEP OUT OFTHE REACH OF CHILDREN Accurately measure t...

Page 21: ...starting point If soft water is not available or practical for you a stain and scale control such as Scale Defense should be added to the spa water according to instructions on its label Once the CH i...

Page 22: ...rspiration etc Chloramines can cause eye irritation as well as having a strong odor Unlike bromamines chloramines are weaker slower sanitizers Chlorine An efficient sanitizing chemical for spas Chlori...

Page 23: ...r level Low pH Low sanitizer level Unsanitary water Free chlorine level above 5 ppm Total alkalinity and or pH too low High iron or copper in source water High calcium content in water total alkalinit...

Page 24: ...F e c a l p e R a p S e z i r e t n i W a p S e z i r e t n i W r e v o C l y n i V n o i t i d n o C n a e l C r e v o C l y n i V n o i t i d n o C n a e l C e c i v r e S e c i v r e S t n e m e l...

Page 25: ...Canada The purchaser must establish the date of purchase by dated sales invoice or delivery receipt This limited warranty does not cover damage resulting from abuse misuse or neglect including any ins...

Page 26: ...1 8 0 0 7 4 9 8 0 0 3 www EliteSpas com 13055 49th St N Clearwater Florida 33762...

Reviews: