No Heat
Temperature Not Set Correctly - Adjust Set Point.
Over temperature error.- Off - On power to reset.
Current Limiting Jumper Is On - LC System (jumper 1 on CB is in right side pos on board.) Will not heat if High Speed or Blower is
on. Contact manufacturer.
No Power - Reset breaker at service panel.
Low Water Flow - Clean or Replace filters(s).
Pressure switch is open - Replace pressure switch with correct setting 1.5 psi.
Low Water level - Add water to spa.
Over Heat
Temperature Sensor Not in Dry-Well - Place sensor in dry-well.
Temperature Set Too High - Adjust Set Point.
High Ambient Temperature - Remove spa cover.
GFCI Trips Occasionally
Lightning or Electrical Storm, Power Surge, Extremely Humid Conditions, or Radio Frequency Interference - Reset GFCI.
NOTE:
GFCI must be properly grounded and bonded.
GFCI Trips Immediately
Defective Component - Contact a qualified service technician or manufacturer for assistance.
Spa Side Control Malfunction
Spa side control cord not plugged - Plug spa side control into system circuit board.
System fuse indicator illuminated - Replace System fuse or replace spa side control.
No Ozone (Ozone generator follows the circulation pump.)
Ozone generator yellow cord not lighted (Circ. Pump on) - Replace electrical pack.
Ozone generator is off and circulation pump is on. Yellow cord lighted - Replace ozone generator.
Spa side control display show a constant 32F or 125F
- Check temperature sensor connection to board. If problem is not resolved
replace the temperature sensor.