               Light Key:  Press this key to turn the light on.  A Second press will turn the Light off.  Spa Light is preprogrammed with 
assortment of lighting effects.  When you turn Light off and turn on within 5 seconds it advances to the next effect.  When you turn 
Light off the more than 5 seconds, it remembers that last effect you selected.  The next time you turn on Light display same effect.  
The Light will automatically shut off after 2 hours.  The Light Icon will appear while the light is on.

                              Temperature Set Keys:  Press the Up Arrow key to increase the desired temperature.  Press the Down Arrow key to 
decrease the temperature.  The temperature can be adjusted in 1 degree F increments from 59 degree F to 104 degree F (5 degree C to 
40 degree C).  The new setting will remain on the display for 5 seconds as a confirmation.  During this time the Set Point icon will be 
appear to let you know this is the desired and not the actual temperature.  After 5 seconds the display will return to the current 
temperature reading.  When the temperature drops to 1 degree F below the set temperature, the heater will be turned on until the 
temperature is 1 degree F above the set temperature.  The heater icon will appear while the heater is on and flash when there is a call 
for heat and the heater has not yet been activated.

START-UP INSTRUCTIONS

PROGRAMMING ANTI STAGNATION CYCLE

Your controls have been designed to provide best spa water quality, maximum convenience as well as economy of operation.  A 24 
hour circulation pump with ozone generator provide efficient, continuous spa water filtration, oxidation and sanitation.  An anti 
stagnation system including both pumps and blower improve even more the spa water quality providing intensive water moving in 
spa, plumbing and air lines to prevent water stagnation.  It is very important in cases the user seldom use the spa.  The anti stagnation 
cycle (AC) consists of starting Jet 2,  Air Jets for 1 minute to purge water and air lines.  Then Jet 1 is turned on in low speed and will 
run for remainder of the AC.  Low speed pump operation helps the water from becoming stagnant and improves filter skimming action 
to remove debris and suspensions from the water surface, minimizing the “bathtub ring” effect.     

AC frequency setting.  To set frequency press and hold Jets 1 Key for 5 seconds.  Use the temperature keys to set AC frequency (1,2 
or 3 times a day).  To save the data press the Jets 1 Key within 5 seconds after adjustment.  If the Jets 1 Key is pressed second time 
with in 5 seconds after adjustment the data will be saved and AC will start immediately.  If the key is not pressed the data will be 
saved and AC will start 12 hours later.  (Default setting is twice per day).  

AC duration setting.  To set duration press and hold Light Key for 5 seconds.  Use the temperature keys to set AC duration.(60, 
120,180,480 minutes).  To save the data press the Light Key within 5 seconds after adjustment.  If the Light key is pressed second 
time with 5 seconds after adjustment the data will saved and AC will start immediately.  If the key is not pressed the data will save and 
AC will start 12 hours later.  (Default setting is 120 minutes). On some spas, default setting can be different. 

9

               
 

 Air Jets Key.  Press this key to turn blower on.  A Second press will turn blower off.  Blower will run for 20 minutes once 

you press the blower key unless you turn it off by pressing the blower key a second time.  Blower can be used to cool the spa.

Setting the water temperature

The spa's thermostat provides optimum control of water temperature. The temperature setpoint can be adjusted from 59F(15C) to 
104F(40C). To raise the set temperature press the Up button. To lower the set temperature, press the Down button. Set point will be 
displayed for 5 seconds. Default setting is 100F.

Activate Pumps, Blower

The Jets1, Jets2 button activates the functions of pump1(two speed) and Pump 2(single speed). By pressing Jets1 will activate pump 1 
in low speed, the second press activates high speed, and third press shuts the pump off. The Jets2 button controls jets pump 2 which 
only operates in high speed. Both pumps have a twenty minute default when manually activated.
The Air Jets button activates Air blower. Blower has twenty minute default when activated manually.

Light Button

. The Light button activates the spa LED Light when pressed. The Light has a two hour default.

Selecting Desired Massage Action

Your spa is equipped to allow you to customize the massage action you desire. The diverter valve allows you to customize the 
massage action and performance by diverting water between various jets systems. Simply turn the diverter to divert water pressure to 
various jet groups as desired pressure

 

Adjusting Individual jet flow    

The water flow to the individual jets in your spa can be increased or decreased by rotating the outside jetface. 

OPERATING INSTRUCTIONS 

Summary of Contents for Platinum I

Page 1: ......

Page 2: ...Diagram Wiring Diagram Specifications Drawing Electrical Wiring Instructions Start Up Instructions Operating Instructions Error Identification Troubleshooting Spa Care and Maintenance Water Quality an...

Page 3: ...call manufacturer WARNING This manual was written to ensure the proper use and installation your spa Any modifications to the procedures outlined in this manual may result in your warranty being void...

Page 4: ...spa may be installed within 5 feet 1 5m of metal surfaces if each metal surface is permanently connected by a minimum No 8 AWG 8 4mm2 solid copper conductor to the wire connector on the terminal box...

Page 5: ...s It is strongly recommended that a qualified licenced contractor prepare foundation for your spa Manufacturer recommends a poured reinforced concrete slab with a minimum thickness of 4 inches 10cm Wo...

Page 6: ...n Box Ground Green To Spa Ground Bar Attached To Box Green Input Out From House To Box Red Input From House To Box Black Input Load Neutral Bar From House To Box Neutral White Input Ground Green Input...

Page 7: ...cification listed may result in damage to equipment and may void the warranty IF THE SPA IS WIRED INCORRECTLY YOUR WARRANTY WILLBE VOID ON ANY BURNED OUT ELECTRICAL EQUIPMENT G F C I Ground Fault Circ...

Page 8: ...h wires as shown in figure 2 to proper connectors Red L2 White N Green GR Black L1 Conector Pressure Switch Fuses SC 25 Fig 4 Panel Screws Pump 1 Pump 2 Air Jets Ozone Aux Heater Indicator Light CONTR...

Page 9: ...WIRING DIAGRAM 5a...

Page 10: ...SPEC SHEET 5b...

Page 11: ...ct to spa 4 The electrical supply for this product must include a suitably rated circuit breaker to open all ungrounded supply conductors to comply with Section 422 20 of the National Electrical Code...

Page 12: ...volume of water so adjust water level to number of people who will be entering spa If your water is extremely hard it is preferable to fill half way with hard water and the rest of the way with soften...

Page 13: ...the side of the spa as show above Figure 8 The main control panel controls all of the spa functions and uses indicator lights and an integrated LED display to aid in determining the status of the spa...

Page 14: ...ure keys to setAC frequency 1 2 or 3 times a day To save the data press the Jets 1 Key within 5 seconds after adjustment If the Jets 1 Key is pressed second time with in 5 seconds after adjustment the...

Page 15: ...ated If 3 flashing dots appear below the temperature display while the pump s is operating turn the pump s off If the 3 flashing dots went away this indicates that the pressure or flow switch was not...

Page 16: ...Pump 1 Pump 1 cord not plugged into receptacle Plug pump 1 into red receptacle Pump 1 fuse indicator illuminated Replace Pump 1 fuse and resume normal operation Pump 1 red plug not lighted Replace Cir...

Page 17: ...l Storm Power Surge Extremely Humid Conditions or Radio Frequency Interference Reset GFCI NOTE GFCI must be properly grounded and bonded GFCI Trips Immediately Defective Component Contact a qualified...

Page 18: ...hased by phone 1 800 749 8003 Part 6136 Filter Elements Care Of The Exterior Spa Shell Your spa shell is made of acrylic Stains and dirt generally will not adhere to the surface Using a soft rag or a...

Page 19: ...riods 5 to 14 days 0 Set temperature to its lowest level approximate water temperature of 80 F Adjust the pH Sanitize the water Lock cover for safety Return Procedures Sanitize the water following sho...

Page 20: ...used correctly they can be hazardous in concentrated form Observe the following guidelines Allow only a responsible person to handle spa chemicals KEEP OUT OFTHE REACH OF CHILDREN Accurately measure t...

Page 21: ...starting point If soft water is not available or practical for you a stain and scale control such as Scale Defense should be added to the spa water according to instructions on its label Once the CH i...

Page 22: ...rspiration etc Chloramines can cause eye irritation as well as having a strong odor Unlike bromamines chloramines are weaker slower sanitizers Chlorine An efficient sanitizing chemical for spas Chlori...

Page 23: ...r level Low pH Low sanitizer level Unsanitary water Free chlorine level above 5 ppm Total alkalinity and or pH too low High iron or copper in source water High calcium content in water total alkalinit...

Page 24: ...F e c a l p e R a p S e z i r e t n i W a p S e z i r e t n i W r e v o C l y n i V n o i t i d n o C n a e l C r e v o C l y n i V n o i t i d n o C n a e l C e c i v r e S e c i v r e S t n e m e l...

Page 25: ...Canada The purchaser must establish the date of purchase by dated sales invoice or delivery receipt This limited warranty does not cover damage resulting from abuse misuse or neglect including any ins...