Light Key: Press this key to turn the light on. A Second press will turn the Light off. Spa Light is preprogrammed with
assortment of lighting effects. When you turn Light off and turn on within 5 seconds it advances to the next effect. When you turn
Light off the more than 5 seconds, it remembers that last effect you selected. The next time you turn on Light display same effect.
The Light will automatically shut off after 2 hours. The Light Icon will appear while the light is on.
Temperature Set Keys: Press the Up Arrow key to increase the desired temperature. Press the Down Arrow key to
decrease the temperature. The temperature can be adjusted in 1 degree F increments from 59 degree F to 104 degree F (5 degree C to
40 degree C). The new setting will remain on the display for 5 seconds as a confirmation. During this time the Set Point icon will be
appear to let you know this is the desired and not the actual temperature. After 5 seconds the display will return to the current
temperature reading. When the temperature drops to 1 degree F below the set temperature, the heater will be turned on until the
temperature is 1 degree F above the set temperature. The heater icon will appear while the heater is on and flash when there is a call
for heat and the heater has not yet been activated.
START-UP INSTRUCTIONS
PROGRAMMING ANTI STAGNATION CYCLE
Your controls have been designed to provide best spa water quality, maximum convenience as well as economy of operation. A 24
hour circulation pump with ozone generator provide efficient, continuous spa water filtration, oxidation and sanitation. An anti
stagnation system including both pumps and blower improve even more the spa water quality providing intensive water moving in
spa, plumbing and air lines to prevent water stagnation. It is very important in cases the user seldom use the spa. The anti stagnation
cycle (AC) consists of starting Jet 2, Air Jets for 1 minute to purge water and air lines. Then Jet 1 is turned on in low speed and will
run for remainder of the AC. Low speed pump operation helps the water from becoming stagnant and improves filter skimming action
to remove debris and suspensions from the water surface, minimizing the “bathtub ring” effect.
AC frequency setting. To set frequency press and hold Jets 1 Key for 5 seconds. Use the temperature keys to set AC frequency (1,2
or 3 times a day). To save the data press the Jets 1 Key within 5 seconds after adjustment. If the Jets 1 Key is pressed second time
with in 5 seconds after adjustment the data will be saved and AC will start immediately. If the key is not pressed the data will be
saved and AC will start 12 hours later. (Default setting is twice per day).
AC duration setting. To set duration press and hold Light Key for 5 seconds. Use the temperature keys to set AC duration.(60,
120,180,480 minutes). To save the data press the Light Key within 5 seconds after adjustment. If the Light key is pressed second
time with 5 seconds after adjustment the data will saved and AC will start immediately. If the key is not pressed the data will save and
AC will start 12 hours later. (Default setting is 120 minutes). On some spas, default setting can be different.
9
Air Jets Key. Press this key to turn blower on. A Second press will turn blower off. Blower will run for 20 minutes once
you press the blower key unless you turn it off by pressing the blower key a second time. Blower can be used to cool the spa.
Setting the water temperature
The spa's thermostat provides optimum control of water temperature. The temperature setpoint can be adjusted from 59F(15C) to
104F(40C). To raise the set temperature press the Up button. To lower the set temperature, press the Down button. Set point will be
displayed for 5 seconds. Default setting is 100F.
Activate Pumps, Blower
The Jets1, Jets2 button activates the functions of pump1(two speed) and Pump 2(single speed). By pressing Jets1 will activate pump 1
in low speed, the second press activates high speed, and third press shuts the pump off. The Jets2 button controls jets pump 2 which
only operates in high speed. Both pumps have a twenty minute default when manually activated.
The Air Jets button activates Air blower. Blower has twenty minute default when activated manually.
Light Button
. The Light button activates the spa LED Light when pressed. The Light has a two hour default.
Selecting Desired Massage Action
Your spa is equipped to allow you to customize the massage action you desire. The diverter valve allows you to customize the
massage action and performance by diverting water between various jets systems. Simply turn the diverter to divert water pressure to
various jet groups as desired pressure
Adjusting Individual jet flow
The water flow to the individual jets in your spa can be increased or decreased by rotating the outside jetface.
OPERATING INSTRUCTIONS
Summary of Contents for Platinum I
Page 1: ......
Page 9: ...WIRING DIAGRAM 5a...
Page 10: ...SPEC SHEET 5b...
Page 26: ...1 8 0 0 7 4 9 8 0 0 3 www EliteSpas com 13055 49th St N Clearwater Florida 33762...