NEUTRAL/GROUND
BAR
INPUTS FROM
TRANSFORMER
HOT
A
HOT
B
HOT
BLK
HOT
RED
WHT
GRN
GROUND
WHT (NEUTRAL)
RED (HO
T)
BLK
(HOT)
GRN (GROUND)
WHT (NEUTRAL)
FROM PANEL NEUTRAL
(GFCI PIGTAIL TO LOAD POST)
G.F.C.I.
SIEMENS
1
2
SPA
120V/240V LOAD
See Page 6
G.F.C.I. HOOK-UP
CONDUIT
C
O
N
D
U
IT
PIGTAIL
CIRCUIT
BREAKER
PANEL
SUB PANEL
Ground GR
POWER REQUIREMENTS
An illustration showing the proper electrical connections for 240 volt service has been provided for you. Be sure
to follow these and all other instructions carefully. Be sure that all connections are tight before switching on the
circuit breaker.
CAUTION!
Failure to abide by specification listed may result in damage to equipment and may void the
warranty.
IF THE SPA IS WIRED INCORRECTLY, YOUR WARRANTY WILL BE VOID ON ANY
BURNED OUT ELECTRICAL EQUIPMENT.
G.F.C.I (Ground Fault Circuit Interrupter)
IMPORTANT
This service must be single phase. High voltage can seriously injure or kill.
Always use a certified
electrician when hooking up your new spa.
The National Electrical Code states that a service disconnect breaker box (a G.F.C.I. can be used for this
purpose) must be located at least 5 feet away from the spa and should be conveniently located near the
equipment bay. If it is not in plain sight, keep the disconnect padlocked when in the off position.
Remember, high voltage is still accessible in the housebreaker box even though you have turned off the spa
breaker.
4
Neutral N
Red L2
Black L1
Fig. 2