background image

18

EN

3. Remote control

Select EQ Presets

Exit menu

Power Off

Power On

Mute button

Volume up

Volume down

Access to the menu 

/ Menu mode 

navigation

Navigation buttons / 
Validation

Manual equalizer

Linear adjustment

Summary of Contents for Infinite A1000

Page 1: ...Mode d emploi User manual Infinite A1000...

Page 2: ...scription 3 1 Face avant 3 2 Face arri re 3 3 T l commande 4 III Branchements connexions 5 1 Entr es haut niveau 5 2 Entr es sym triques 6 3 Entr es asym triques 6 4 Sorties asym triques 6 5 Trigger 7...

Page 3: ...dans le menu Port USB 2 Face arri re Entr es haut niveau Entr e sym trique Entr es asym triques Sorties asym triques Entr e Trigger 12V Entr e capteur infrarouge d port 3 5mm Sortie caisson de grave...

Page 4: ...isation du DSP Sortie du menu Bouton d extinction Bouton d allumage Bouton Mute Augmenter le volume Diminuer le volume Acc s au menu Navigation des modes du menu Navigation dans le menu Validation gal...

Page 5: ...er permettent de connecter un amplificateur st r o ext rieur ainsi qu une paire d enceinte st r o sur ces m mes bornes L amplificateur externe assure ainsi la gestion des enceintes st r o L amplificat...

Page 6: ...m triques avec un signal d entr e st r o de niveau ligne En sortie l amplificateur A1000 r alise la somme des deux canaux gauche droite afin de sortir un signal mono 4 Sorties asym triques Pour export...

Page 7: ...gauche et droite enfonc es tout en mettant l amplificateur sous tension l aide de l interrupteur d alimentation arri re Le mode trigger sera d sactiv et l amplificateur s allumera 6 Port infrarouge V...

Page 8: ...er le param tre voulu appuyez sur le bouton de l amplificateur ou sur le bouton Menu Enter de la t l commande Remarque Un appui prolong sur le bouton de l amplificateur permet celui ci d tre en standb...

Page 9: ...ponible uniquement en mode Sub Mode select Le Mode Select permet de commuter l amplificateur entre les modes LFE et SUB En mode LFE la pente du filtre et les r glages de fr quence sont d sactiv s La f...

Page 10: ...ficateur de s allumer et de s teindre en fonction de la pr sence d un signal audio Lorsqu il est r gl sur OFF la fonction est d sactiv e et l amplificateur reste allum en permanence Lorsqu il est sur...

Page 11: ...r le point III 5 Trigger page 7 Utilisez les boutons Gauche et Droite pour d finir et Menu pour enregistrer Store Data Select Le r glage Store Data est utilis pour sauvegarder les changement manuels a...

Page 12: ...ctave ENTER Preset 1 7 flat User S lection du mode d EQ En mode USER possibilit de r glage simplifi de l EQ bande ENTER S lection de la bande d octave 19 7 125Hz et ajustement de son gain 3 6dB ENTER...

Page 13: ...204 Hz R glable 12dB 48dB par octave incr ments de 6dB 9 fr quences tierces ind pendantes 19 7 Hz 125 Hz avec une plage de 6dB 3dB 7 r glages d galisation pr d finis en usine d pend de l application R...

Page 14: ...envisagez de ne pas utiliser cet appareil pendant une p riode prolong e d branchez le du secteur N ouvrez pas le coffret Cet appareil ne contient aucune pi ce changeable par l utilisateur L acc s l i...

Page 15: ...15 FR...

Page 16: ...ons 27 Warnings Warranty 28 TABLE OF CONTENTS I CONTENT OF THE BOX Before use please check that the following accessories are in the box Dear Customer Thank you for choosing Elipson products Take time...

Page 17: ...een display Volume navigation button USB port 2 Rear panel High level inputs Balanced input Unbalanced inputs Unbalanced outputs 12V Trigger input External IR input 3 5mm Subwoofer output Power switch...

Page 18: ...N 3 Remote control Select EQ Presets Exit menu Power Off Power On Mute button Volume up Volume down Access to the menu Menu mode navigation Navigation buttons Validation Manual equalizer Linear adjust...

Page 19: ...h level speaker inputs are used to connect an external stereo amplifier and a pair of stereo speakers to these terminals The external amplifier manages the stereo speakers The amplifier A 1000 supplie...

Page 20: ...d RCA cables to a line level stereo input signal At the output the amplifier A1000 carries out the sum of both left right channels in order to provide a mono signal 4 Unbalanced outputs To export the...

Page 21: ...own the left and right navigation keys while turning on the amplifier using its rear power switch The trigger mode will be disabled and the amplifier will turn on 6 IR Port You can connect an external...

Page 22: ...e control To select the desired parameter press the amplifier button or the Menu Enter button on the remote control Note A long press on the amplifier button allows it to go in standby mode A short pr...

Page 23: ...fier to switch between LFE or SUB mode In LFE mode the crossover slope and frequency adjustments are disabled The crossover frequency should then be set by an external processor receiver Use Left and...

Page 24: ...on and off based on the presence of an audio signal When set to OFF the function is disabled and the amp stays on constantly When set to ON the amplifier is controlled by the presence or absence of au...

Page 25: ...r signal and turn the amp on by doing a special power on sequence see III 5 Trigger page 21 Use Left and Right buttons to set and Menu to save Store Data Select The Store Data setting is used to save...

Page 26: ...from 12db to 48dB per octave ENTER Preset 1 7 flat User Selection of EQ mode In USER mode you can easily adjust the band EQ ENTER Selection of the octave band 19 7 125 Hz and adjustment of its gain 3...

Page 27: ...er octave 6dB increments 9 independent third frequencies 19 7 Hz 125 Hz with a 6dB 3dB range 7 EQ presets set in factory depends on the application Adjustable from 0 to 315 45 increments Sub crossover...

Page 28: ...r a technician to remove it from the device to ensure safety The appliance coupler is used as disconnect device the disconnect device shall remain readily operable The apparatus shall not be exposed t...

Page 29: ...29 EN...

Page 30: ......

Page 31: ......

Page 32: ...www elipson com 24 07 2018...

Reviews: