# Warning message
Possible cause
Troubleshooting operations
Error 05 TEST RELAY
The machine is on but does not weld:
a)
Power supply issues.
b)
Check the connection to the
electrical grid;
c)
Replace the electrical power cable.
Error 06 TEST VDC
The electronics have failed to load the
capacitor bank:
a)
The generator is broken.
Please contact the
Elettrolaser
Customer Service.
Error 07 MOTOR RESET KO
The motor regulating the shot diameter
fails to move.
Turn the machine off and back on again.
The machine will repeat all checks on
the motor. If the error persists, please
contact the
Elettrolaser Customer
Service.
Error 12 INTERLOCK OPEN!
The interlock is disconnected.
Reconnect or please contact the
Elettrolaser Customer Service.
Tab. 8-4
–