Horizontal Wall Termination
Trisore 70/ Bidore 70/ Modore 70 Trisore 95/ Bidore 95/ Modore 95
Diameter Concentric Flue: 200/130
Trisore 70, Bidore 70 and Modore 70 can be installed with a 90 degree bend direct to the fire.
Minimal vertical height “V” is 0,5 meters (95-models)
Maximum height “V” whilst using a wall terminal: 3 meter
Horizontal possibilities:
0,5 meter vertical gives maximum horizontal 2 meter
1,0 meter vertical gives maximum horizontal 4 meter
1,5 meter vertical gives maximum horizontal 6 meter
2,0 meter vertical gives maximum horizontal 8 meter
Trisore 140/ Bidore 140/ Modore 140
Diameter Concentric Flue: 200/130
Minimal vertical height “V” is 0,5 meter
Maximum vertical height “V” whilst using a wall terminal: 3 meter
Horizontal possibilities Trisore 140/ Bidore 140/ Modore 140:
0,5 meter vertical gives maximum horizontal 0,5 meter
1,0 meter vertical gives maximum horizontal 1 meter
1,5 meter vertical gives maximum horizontal 1,5 meter
2,0 meter vertical gives maximum horizontal 2 meter
3,0 meter vertical gives maximum horizontal 3 meter
21
INSTALLER INFORMATION
Rigid Balanced Flue Connection Possibilities
Horizontal Wall Termination
Bidore 70/ Trisore 70/ Modore 70
Diameter Concentric Flue: 200/130
Bidore 70 and Trisore 70 can be installed with a 90 degree bend direct to the fire.
Minimal vertical height “V” is the height of a 90 degree bend (20 cm)
Maximum height “V” whilst using a wall terminal: 3 meter
Horizontal possibilities:
0,5 meter vertical gives maximum horizontal 3 meter
1,0 meter vertical gives maximum horizontal 6 meters
1,5 meter vertical gives maximum horizontal 9 meter
Modore 95 /Bidore 95/ Trisore 95
Modore 140/ Bidore 140/ Trisore 140
Diameter Concentric Flue: 200/130
Minimal vertical height “V” is 0,5 meter
Maximum vertical height “V” whilst using a wall terminal: 3 meter
Horizontal possibilities Modore95/Bidore95/Trisore95:
0,5 meter vertical gives maximum horizontal 2 meter
1,0 meter vertical gives maximum horizontal 4 meter
2.0 meter vertical gives maximum horizontal 8 meter
Horizontal possibilities Modore140/Bidore140/Trisore140:
0,5 meter vertical gives maximum horizontal 1,5 meter
1,0 meter vertical gives maximum horizontal 3 meter
2.0 meter vertical gives maximum horizontal 6 meter
Summary of Contents for Bidore 140
Page 15: ...15 INSTALLER INFORMATION 15 INSTALLER INFORMATION ...
Page 16: ...16 INSTALLER INFORMATION 16 INSTALLER INFORMATION ...
Page 17: ...17 INSTALLER INFORMATION 17 INSTALLER INFORMATION ...
Page 18: ...18 INSTALLER INFORMATION 18 INSTALLER INFORMATION ...
Page 30: ...30 INSTALLER INFORMATION 30 INSTALLER INFORMATION ...
Page 45: ...45 TECHNICAL INFORMATION 45 TECHNICAL INFORMATION PIN 0359CN1268 PIN 0359CN1268 Modore 140 ...
Page 47: ...47 ...
Page 48: ...Element4 B V Paxtonstraat 23 8013 RP Zwolle The Netherlands September 2014 ...