Resistance Welder MULTISPOT MI-100
Health and safety
13
2.6 Safety
devices
Fig. 1:
Power switch on the backside
Power switch
Turning the power switch to position "
0
" will disconnect the power
supply immediately.
WARNING ! Danger! Equipment may still be under voltage.
After switching off the power switch on the backside of the equipment, there may still be
components inside that are still under voltage. Therefore:
In order to disconnect this equipment from the power supply, switch off using the power
switch. Earth components, short circuit and check for residual electricity.
2.7
Safety labels and markings on this
equipment
Fehler! Textmarke nicht
definiert.
2.7.1
On the flap cover
Fig. 2: Warning sign
"Electromagnetic fields"
on the flap cover
Meaning
Welding generates electromagnetic fields. Electromagnetic fields pose a potentially
fatal hazard to people with pacemakers or other magnetisable implants.
Electromagnetic fields also affect magnetisable objects, like e.g. watches, smart
cards etc.
DANGER ! Electromagnetic fields pose a mortal danger to persons with pacemakers.
Electromagnetic fields affect the functionality of pacemakers and other magnetisable implants.
Electromagnetic fields can irritate human sense organs, nerve and muscle cells. Therefore:
Persons with pacemakers or other magnetisable implants must not approach the working
area.
Be sure to put up suitable warning signs.
Be sure to put warning signs on access ways and doors leading to the work area.
Do not guide welding cables along people's heads or spines. Keep a distance of at least
1 cm.
WARNING! Danger! Due to insufficient protection against residual current!
Connection to electrical socket: the device may only be plugged into a socket with a residual current
device and an operable earthing device.