Page 28
FUNCTION OVERVIEW
•
Control panel for ELEKTROMATEN
®
up to. 3 kW at 400V / 3~ with electronic limit
DES
designed for only low-level adjustment
•
7- Segment led display showing
- Programming the control panel
- Displays Command - / Info- / Fault
•
Mains supply
- 400V / 3~ with and without Neutral
- 230V / 3~
- 230V / 1~ (for single-phase motors)
•
Door operating modes
- Dead-man open- and close
- Self-hold open- and dead-man mode close
- Fully closed control
•
Supply for external devices
- 230V (at 400V / 3~ with N), up to 1A load
•
Plug for 5 pole motor connector 6 pole for electronic limit DES
•
Plug for spiral cable pass-door contact
•
Integrated internal pushbutton OPEN / STOP / CLOSE
•
Additional terminals for different control equipment
- Emergency stop ( LATCHING)
- Additional safety stops
- External three push button OPEN / STOP / CLOSE
- Key switch ( latching) for intermediate Stop
- 1x potential free relay output (NC / NO), switching contact continous or impulse