Page 25
TECHNICAL DATA
Housing Dimensions
190mm x 300mm x 115mm
(W x H x D)
Mounting
vertical
ELEKTROMATEN
®
Supply
Three-phase 3 x 230 / 400V AC ± 5%, 50...60Hz
Single-phase 1 x 230V ± 5%, 50...60Hz
Power max. at 3 x 400V AC, max. 3kW
Control supply via L1,L2
400V AC or 230V AC + - 10%, 50-...60Hz,
voltage changing with bridge to 3- pole terminal,
safety fuse F1 (1A t)
External supply fuse
10A delayed
Permitted Load
ca. 15 VA (without motor and ext. 230V)
External supply
230V via L1 and N, safety fuse F1 (1A t)
Inputs
24V DC / typ. 10mA
signal length must be more than 100ms
Relay output
If inductive loads are to be switched (e.g. other relays)
those have to be protected with free-wheeling Diodes
contact load at 230V max. 1A
Temperature
Working: +0.... +40°C
Storage: +0....+50°C
Humidity:
To 93% not condensing
Vibration:
Vibration free mounting, e.g. on flat built wall
Protection class
IP54 (CEE Plug), IP65 available
www.gfa-elektromaten.de