After the Mains supply has been connected by inserting the CEE plug in the
appropriate socket or turning on the main switch, confirm that the phase rotation
is correct by checking that the door opens when the OPEN push button is
operated.
If the door closes when operating the OPEN push button reverse two phases
at the terminal X1.

PHASE ROTATION

DANGER! To the life and health through electric shock.

Before changing phase rotation the mains supply must be switched OFF.

Three-phase 3 x 400 V AC, N, PE

Star connection

Three-phase 3 x 230 V AC, PE

Delta connection

Single-phase 1 x 230 V AC, N, PE

symmetrical winding

Single-phase 1 x 230 V AC, N, PE

asymmetrical winding

Important note!

For 3x400V AC PE no
neutral, the brake
rectifier must be
connected between
terminal V and star-
point terminal.

brown

brown

supply for
brake
rectifier

blue

supply for
brake
rectifier

MOTOR CONNECTION (internal wiring)

blue

On several ELEKTROMATEN

®

 the connection U1 und V1 on the motor-plug are

interchanged.

Summary of Contents for TS 958

Page 1: ...Electrical operating instructions Door control panel TS 958 Software 1 2 Design and functions subject to change 51171324 g 02 2013 en...

Page 2: ...NNECTION internal wiring 10 RAPID ADJUSTMENT OF THE LIMITS 11 HARDWARE OVERVIEW 12 WIRING DIAGRAM 13 CONTROL PROGRAMMING 14 Operating mode 15 Door position 15 Functions 15 Safety functions 15 Maintena...

Page 3: ...19 Fully closed control 19 Potential free changeover contact X9 19 Door overload monitor 20 Maintenance cycle counter 21 Short circuit overload monitor 21 OPERATING STATUS DISPLAY 22 TECHNICAL DATA 2...

Page 4: ...arage doors and gates Safety in use of power operated doors Requirements and left the factory in perfect condition from the point of view of safety To maintain this condition and to ensure safe operat...

Page 5: ...ate back up fuse must be provided Check live cables and conductors regularly for insulation faults or breakages When a fault is detected in the cabling the defective cabling should be replaced after i...

Page 6: ...l page 8 Check Mains supply page 9 Check Phase rotation page 10 Programming Rapid limit adjustment page 11 The door is ready to work Installation Spiral cable if required page 13 19 Programming Door f...

Page 7: ...tton Emergency stop Switch contact potential free Connection cable ELEKTROMAT for Motor and DES electronic limit 11 5 3 3 Spiral cable 2 Number of cores in the cable Important Using the connection cab...

Page 8: ...trol are fitted they can be connected with a plug in cable The cable has plugs on each end and for easy fitting The plugs for motor and control panel are different and cannot be interchanged Connectio...

Page 9: ...he right terminal otherwise the print could be destroyed 400V mains supply 1 5 1 6 230V mains supply 1 6 1 7 MAINS SUPPLY External fuse Control must be saved against short circuit and overload by an e...

Page 10: ...hrough electric shock Before changing phase rotation the mains supply must be switched OFF Three phase 3 x 400 V AC N PE Star connection Three phase 3 x 230 V AC PE Delta connection Single phase 1 x 2...

Page 11: ...changes 3 Setting the final limit close press button to reach lower limit Display blinking Door close 4 Memorise the final limit close Press stop button for 3 sec until the display changes Display cha...

Page 12: ...gment display 1 9 L1 fused with F1 1A MOT Motor connection 1 8 N DES Limit connection only with 3 x 400V N PE und 1 x 230V N PE Internal push button X2 Safety edge system and pass door plug X3 Emergen...

Page 13: ...ation Key switch with stop button Close Stop Open Stop Open Close Key switch intermediate stop Aux contact Bridge passdoor slack wire switch contact spiral cable Open Close or plug in bridge or Emerge...

Page 14: ...Enter programming Mode Press selector switch for 3 sec until display 00 2 Chose program and confirm Turn selector Press selector 3 Adjustment Turn selector Press foil buttons 4 Memorise Press selector...

Page 15: ...position Relay switch position Press stop Button Press selector Press selector Press stop Button Move door upwards or downwards Final limit close coarse adjustment Final limit open can change without...

Page 16: ...es Counter adjustment Display appears CS and adjusted number of cycles Reaction when reaching 0 Maintenance cycle counter 4 Set 3 Adjustment 2 Chose program and confirm Press selector Press selector C...

Page 17: ...on M HT ZT T H Z E Press selector Press selector M HT ZT T H Z E The cycles would be displayed as follow M 1 000 000 H 100 HT 100 000 Z 10 ZT 10 000 E 1 T 1 000 The Number of program changes would be...

Page 18: ...PEN command is given after the door controller has detected beforehand asymmetrical pass door switch positions see below for reasons This fault can be reset when the door is reopened This ensures that...

Page 19: ...cable Push the plugs through into the enclosure until there is sufficient cable to allow the plug to be connected to the board If passdoor slack wire switch contact exists remove bridge at terminal S...

Page 20: ...force monitoring the door must perfom a complete opening and closing cycle without an interruption Durich which the system reads the increments to calculate the way Important Note The overload monito...

Page 21: ...nance is agreed The no of cycles can be adjusted from 1 000 up to 99 000 the adjustment is possible in steps of 1 000 cycles Different reactions can be chosen if the point of pre adjusted maintenance...

Page 22: ...contact open X 2 1 X 2 2 Check the proper operation of pass door contact or whether the supply cable is broken Emergency stop activated Check the emergency stop is activated or whether the supply cabl...

Page 23: ...tion turning Check phase rotation Phase rotation failure Check main supply phase rotation turns right Check electronic limit DES connection To acknowledge the fault switch OFF ON on the mains or disco...

Page 24: ...ose command being given Report Command description closing door stopped between set limits Report Status door stopped at upper limit door stopped at lower limit opening flashing flashing adjusted cycl...

Page 25: ...rnal supply fuse 10A delayed Permitted Load ca 15 VA without motor and ext 230V External supply 230V via L1 and N safety fuse F1 1A t Inputs 24V DC typ 10mA signal length must be more than 100ms Relay...

Page 26: ...we recommend a replacement for control boards in use after doors having reached their confirmed lifetime cycles Coherence between power and amount of cycles for ELEKTROMATEN describes diagram bellow...

Page 27: ...ant technical documents internal EU address Dipl Ing Bernd Synowsky Documentation representative Incomplete machines within the meaning of the EC Directive 2006 42 EC shall only be intended to be inte...

Page 28: ...and close Self hold open and dead man mode close Fully closed control Supply for external devices 230V at 400V 3 with N up to 1A load Plug for 5 pole motor connector 6 pole for electronic limit DES P...

Reviews: