Page 22
OPERATING STATUS DISPLAY
The control TS 958 can display up to three different status conditions one after another.
Each status is displayed with a letter and a number. The letter and the number are flashing
alternately, thereby the control differentiates between a FAULT =
F
and a command =
E.
Report
Description
Measure to solve the problem
Emergency operator or
motor-winding thermal
protection operated
Check emergency operator or whether the drive unit
is overloaded.
Pass door contact open
X 2.1- X 2.2
Check the proper operation of pass door contact, or
whether the supply cable is broken
Emergency stop activated
Check the emergency stop is activated, or whether
the supply cable is broken
Failure pass door contact
X 2.1- X 2.2 or control voltage
circuit less than 24V
Failure input pass door
X 2.1- X 2.2
Check pass door circuit’s transition resistance and
weather pass door switch works. To acknowledge the
fault open and close the pass door switch, off and on
the main switch, or disconnect and reconnect the mains
plug.
To acknowledge the fault switch off and on the main
switch or disconnect and reconnect the mains plug.
If necessary replace the control panel.