Page 11
RAPID ADJUSTMENT OF THE LIMITS
The Rapid adjustment is finished
The door could be moved in DEADMAN mode UP/DOWN
Further adjustments see programming mode
1. Setting final limit open
press button to reach upper limit
Door open
Display
blinking
2. Memorise the final limit open
Press stop-button for 3 sec. until
the display changes
Display
changes
3.Setting the final limit close
press button to reach lower limit
Display
blinking
Door close
4. Memorise the final limit close
Press stop-button for 3 sec. until
the display changes
Display
changes
When the phase rotation has been checked the Rapid limit adjustment can be made.
The final setting can be made with the fine adjustment (Control Programming page 15).
Safety limits and pre-limits are automatically adjusted.
The final limit OPEN is memorised when the door moves for at least one second
from close into the upper limit position.