Electrical connection
29
W5180H
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended
fuse
A
200V 3 ~
50/60
12.5
12.9
50
220–240V 3 ~
50/60
9.1–10.8
9.4–11.1
35
220–240V 3 ~
50/60
15.1–18.0
15.5–18.3
50
380–415V 3 ~
50/60
9.0–10.8
9.4–11.1
20
380–415V 3 ~
50/60
15.0–17.9
15.4–18.3
35
Electric heated
440/480V 3 ~
60
18.0
18.4
25
Non heated/Steam heated
200V 3 ~
50/60
-
2.4
10
Max. permitted impendance* = 0.26 Ohm
W5240H
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended
fuse
A
200V 3 ~
50/60
14.4
14.8
50
220–240V 3 ~
50/60
16.6–19.8
17.0–20.1
50
380–415V 3 ~
50/60
16.5–19.7
17.0–20.2
35
Electric heated
440V/480V 3 ~
60
21.0/22.8
21.4/23.3
35
200V 3 ~
50/60
-
2.6
10
Non heated/Steam heated
440V/480V 3~
60
-
2.2
10
Max. permitted impendance* = 0.26 Ohm
W5300H
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended
fuse
A
200V 3 ~
50/60
14.4
15.0
50
220–240V 3 ~
50/60
16.6–19.8
17.2–20.3
63
380–415V 3 ~
50/60
16.5–19.7
17.1–20.3
35
Electric heated
440V/480V 3 ~
60
21.0/22.8
21.5/23.4
35
200V 3 ~
50/60
-
2.7
10
Non heated/Steam heated
440V/480V 3 ~
60
-
2.2
10
Max. permitted impendance* = 0.26 Ohm
* The impendance in the mains connected point in accordance with EN31000–3–11. If the
impendance in the mains connected point is higher than stated, check with the power supplier.