Connection of external dosing systems
19
5 Connection of external dosing systems
5.1 Connection of the hoses
The machine is prepared for connection of external dosing systems or water re-use systems etc.
The connections are closed at delivery. Open any of the connections that shall be used by drilling
a hole where the hoses shall be connected.
Note!
Make sure there is no burrs left after drilling. When removing burrs make sure burrs does
not fall into the siphon breaker.
A =
⌀
17 mm (used for external dosing systems or systems for re-use of water).
B =
⌀
6 mm (used for external dosing systems only).
C = Only used for external liquid manifold. (Separate instructions enclosed when ordering).
⑨
A
B
C
Always connect hoses on connections A with a hose clamp.
For connections B; if the hoses are made of a soft material such as silikon or similair, use a
cable tie to fasten the hose on the connection. If the hoses are made of a hard material, it is not
recommended to make the connection tighter by using a cable tie.
Note!
Equipment for external dosing must only be connected to work on pump pressure and
not on network pressure.