Page 71 KSSSI116
Communication Fault Continues:
# Check the
continuity
of the connecting wires from the outdoor PCB to the Reactor, as listed
below.
Orange terminal point on outdoor PCB to orange terminal point on Reactor.
White terminal point on outdoor PCB to white terminal point on Reactor.
Check the continuity of the reactor. If open circuit, change it.
Orange & White connecting wires from outdoor PCB to Reactor.
Resistance reading of Reactor.