Page 41 KSSSI116
Cooling Mode:
Cooling Conditions and Process (KSV53, 62, 70 & 80CRC/HRC)
When the (indoor ambient temperature - Tamb.) is >3ºC above the (indoor preset temperature - Tpreset), the unit starts
cooling operation. In this case, the compressor and the outdoor fan operate and the indoor fan operates at set speed.
When (indoor ambient temperature - Tamb.) -3ºC below the (indoor preset temperature - Tpreset), the compressor and
the outdoor fan stop, while the indoor fan runs at set speed.
In cooling mode, the temperature setting range is 16
~
30ºC, Indoor unit displays operation icon, cooling icon and set
temperature.