106
2. Remove the (8) screws, four on each end, holding
the back cover to the side panels and lift the back
cover off.
Removing the convection fan motor:
1. Disconnect power and remove the back cover.
2. Remove the convection fan blade and disconnect
the wires from the motor.
3. Using a ¼” nut driver, remove the three screws
holding the motor to the rear of the oven and pull
the motor straight back.
Removing the rear air channel cover :
1. Disconnect power and remove the back cover.
2. Remove the (8) screws holding the cover to the air
channel and lift the cover off.