55
E9C
E9C: User Interface Configuration Problem
E9C
Main Circuit Board defective, Motor Control Board defective, Wiring problem.
Checks to perform:
E9E
E9E: Key Stuck or Contaminated
E9E
User Interface Board defective , Control Panel defective.
Checks to perform:
WARNING
Check that all the connectors are correctly
inserted.
WARNING
Check that all the connectors are correctly
inserted.
Disconnect the connector J16 which connects Electronic control
Board and J5 of User Interface Board. Does the E9C error appear
again?
Y
E
S
Check the wiring between the Main Control Board and the User
Interface Board.
• Detach and reconnect the connectors on both boards several
times.
• Measure the continuity between connector J16 (Main Control
Board) and J5 (User Interface Board).
Is the wiring OK?
Y
E
S
Replace the User Interface Board, and repeat the diagnostic cycle
to check for any further errors. Is the Appliance still displaying E9C?
Replace the Main Control Board,
and repeat the diagnostic cycle to
check for any further errors.
Replace / Repair the wiring, and
repeat the diagnostic cycle to
check for any further errors.
NO
NO
Appliance is OK.
NO
Y
E
S
Replace the Main Control Board, and repeat the diagnostic cycle to
check for any further errors.
Clean buttons and spring alignment in User Interface assembly. Is the Appliance still displaying E9E? If yes, then
replace User Interface Board and repeat the diagnostic cycle to check for any further errors.
Troubleshooting Based on Error Codes
Summary of Contents for EFLS417SIW
Page 2: ...2 ...
Page 8: ...8 4 Product Features 4 1 EFLS617SIW EFLS517SIW EFLS417SIW ...
Page 16: ...16 7 2 3 Main Control Board Electrical Characteristics ...
Page 17: ...17 7 3 Wiring Diagram EFLS617SIW EFLS517SIW EFLS417SIW Electrical Characteristics ...