19
WARNING
When replacing the Pump, please refer to the
code shown in the list of spare parts relating to
the Appliance.
8.1 Pump
There are more than one pumps used for this model:
• Drain Pump
• Recirculation Pump
• Concentrated Wash Pump
8.1.1 General Characteristics
1. Wheel
2. Rotor
3. Stator
The Drain pump, which
drains the water at the end
of the various washing
cycle phases, is centrifugal
and is activated by a
synchronous motor. Also,
Recirculation Pump is used
for recirculating the wash
water.
The rotor consists of a
permanent magnet and
the direction of rotation
can be either clockwise or
anticlockwise.
It can turn by approximately
a quarter of a revolution
without turning the wheel.
Consequently, if a foreign
body is stuck in the wheel, the rotor can perform small
movements clockwise and anticlockwise until the
foreign body is released.
IMPORTANT
Synchronous pumps, when powered on empty
(disconnected from the water circuit), may
not start in some cases because their very
construction makes them need an antagonist
torque on the wheel to allow the rotor to move in
one of the two directions.
The pumps should therefore only be tested once fitted
to the Appliance after a little water has been filled.
The pumps are powered by the Main Control Board
through a TRIAC.
Component Specifications
S. No. Component
Specifications
1
Drain Pump
Rated-120 VAC / 60 Hz,
Working Voltage-95-132
VAC, Current and Power
with Rotor locked-1.4 A
80 W Max. (Winding
Resistance-14 ± 10% Ω)
2
Recirculation
Pump (Not
applicable for
417 series)
Nominal Voltage-120 V, 60
Hz, Insulation Class F (155),
Working Voltage 95-132 V
(Resistance-31.5 ± 10% Ω
@20 ºC)
3
Concentrated
Wash
Pump (Not
applicable for
417 and 517
series)
Nominal Voltage-120 V, 60
Hz, Insulation Class F (155),
Working Voltage 95-132 V
(Resistance-31.5 ± 10% Ω
@20 ºC)
8.2 Heating Element
(Not applicable for 417 series)
8.2.1 General
Characteristics
1. NTC probe
2. Heating element
The heating element of the washing water is
armoured, that is, it is inserted in sealed tubular
stainless steel casing. It is powered by Main Circuit
Board. It is fitted with two thermal fuses which trip if
Electrical Components –
EFLS617SIW / EFLS517SIW / EFLS417SIW
Summary of Contents for EFLS417SIW
Page 2: ...2 ...
Page 8: ...8 4 Product Features 4 1 EFLS617SIW EFLS517SIW EFLS417SIW ...
Page 16: ...16 7 2 3 Main Control Board Electrical Characteristics ...
Page 17: ...17 7 3 Wiring Diagram EFLS617SIW EFLS517SIW EFLS417SIW Electrical Characteristics ...