E62
E62: Wash Temperature Too High
E62
NTC defective, Wiring problem.
Checks to perform:
(Not applicable for 417 series)
WARNING
Check that all the connectors are correctly
inserted.
Y
E
S
Is the resistance measurement of the Drum water NTC ranges from
4.5 KΩ to 5.5 KΩ at 25 °C? (Measure it directly on the Drum water
NTC without wiring.) (See Fig. 1)
Replace the NTC, and repeat the
diagnostic cycle to check for any
further errors.
NO
Reconnect the connector and measure the resistance ranges
from 4.5 KΩ to 5.5 KΩ at 25 °C. On the Drum water NTC wiring
connector on the Main Control Board between J12-4 and J12-5, Is
the Inlet NTC Valve wiring OK? (See Fig. 2)
Y
E
S
Replace the Main Control Board and repeat the diagnostic cycle
to check for any further errors.
Replace the wiring, and repeat the
diagnostic cycle to check for any
further errors.
NO
Y
E
S
Check if the resistance between the terminals of Heating Element is
approximately 14 Ω ± 5%? (See Fig. 3)
Replace the Heating Element and
repeat the diagnostic cycle to check
for any further errors.
NO
Check the resistance between ground and both heater terminals
when the heater terminals are disconnected. Is Resistance value
not “0”? (See Fig. 4)
Replace the Heating Element and
repeat the diagnostic cycle to check
for any further errors.
NO
Y
E
S
Troubleshooting Based on Error Codes
Summary of Contents for EFLS417SIW
Page 2: ...2 ...
Page 8: ...8 4 Product Features 4 1 EFLS617SIW EFLS517SIW EFLS417SIW ...
Page 16: ...16 7 2 3 Main Control Board Electrical Characteristics ...
Page 17: ...17 7 3 Wiring Diagram EFLS617SIW EFLS517SIW EFLS417SIW Electrical Characteristics ...