Possible failures of the meat probe feature are:
• Loose wire or harness connection.
• Defective meat probe.
• Defective receptacle and wiring harness.
• Defective Electronic Oven Control.
To troubleshoot the meat probe feature first test the probe itself
by using an ohm meter to measure resistance. Place one of the
meter leads on the very tip of the probe plug and the other lead
on the adjacent short segment as indicated in the photo.
The resistance will vary depending on the actual temperature of
the probe. At a room temperature of 77 degrees the resistance
will measure approximately 46,000 ohms.
To test the accuracy of the probe place the metal wand end into a container of water that has a
temperature of 120 degrees Fahrenheit and measure the resistance. At 120 degrees the resistance
should be between 17,860 ohms and 19,740 ohms. If the resistance is incorrect replace the probe.
If the probe resistance is correct plug the probe into the receptacle inside the oven and disconnect
the probe harness connector from the E O C connection P 18.
Measure the resistance between the two
wires in the harness plug. If the resistance is
approximately equal to the resistance of the
probe then the harness and receptacle circuit
are good.
If the resistance is significantly higher or lower than that of the probe then the receptacle and wiring
harness should be replaced. The receptacle and wiring harness are replaced as an assembly.
If the probe, receptacle and harness are good but the probe feature does not work the failure is in the
E O C and it must be replaced.
Probe Resistance
Test Points
Probe Harness
Connector P 18
Troubleshooting
Theory Of Operation
Some models feature a meat probe that is used to monitor the internal temperature of the food during
cooking. The meat probe is a RTD (Resistance Temperature Device) similar to the oven temperature
sensor found in ranges with electronic oven controls. As the temperature of the meat probe increases
the resistance decreases. The E O C monitors this resistance whenever the probe is inserted into the
receptacle and uses this information to determine when the food has reached the target temperature.
Component Parts
The components of the meat probe
feature are: Probe assembly (Fig 1 )
and the receptacle assembly which
includes the wire harness (Fig 2 ).
Fig 1
Fig 2
MEAT PROBE FEATURE
Summary of Contents for CEI30EF5GB
Page 11: ...Page 11 Wiring Diagram Electric Wave Touch Models with Lower Oven ...
Page 12: ...Page 12 Schematic Diagram Electric WaveTouch Models with Lower Oven ...
Page 13: ...Page 13 Wiring Diagram Electric IQ Touch Models with Warming Drawer ...
Page 14: ...Page 14 Schematic Diagram Electric IQ Touch Models with Warming Drawer ...
Page 46: ...Page 46 ...
Page 47: ...Page 47 NOTES ...