Gas Cooktops  LP CONVERSION - DONG YANG  9

installation

LPG conversion -  

DONG YANG regulator

Checking the gas supply

1.  Check the manometer zero point is correct.
2.   Connect the manometer to the cooktop pressure point. This 

is located on the regulator.

3.   Turn on the gas supply and electricity and try to ignite  

the gas. 

TIPS & INFORMATION

 tips & information

It will take additional time to light the gas for the first time as 

air needs to be purged from the pipes.

4.   With the appliance operating check the outlet pressure:
•    when all burners of the appliance are operating  

at maximum,

•  when the smallest burner of the appliance  

is operating at minimum.

Under these conditions the outlet pressure should not vary 

from the nominal outlet pressure of 1.00kPa by more than 

+/–0.20kPa.
If the regulator appears to not be performing satisfactorily, 

then check the following points.
1.   If the outlet pressure is consistently too low then the inlet 

pressure may be too low and adjustment of an upstream 

regulator may be needed, or an upstream regulator or 

valve with insufficient flow capacity may be present in the 

gas supply line. If this is suspected then it may be necessary 

to repeat the checks whilst  

measuring both the inlet and outlet pressure to determine  

if the inlet pressure is in the range 1.13 – 5kPa.

2.   Check that the regulator has been fitted to the gas supply 

line in the correct orientation, the arrow on the base of the 

body indicates the direction of gas flow.

Once these checks have been completed, if the regulator 

still fails to perform in a satisfactory manner it should be 

replaced.

TIPS & INFORMATION

 tips & information

Refer to page 10 if you have been supplied with a  

CHANT regulator.

This appliance is fitted with Natural Gas burner injectors.

Please follow the procedure below if a conversion to suit LP 

gas is required.

 

The conversion kit contains appropriate LPG 

injectors and 1 LPG sticker.

To convert to LPG

1.   Remove the hotplate burners to access the hotplate 

injectors. Replace the factory fitted NG injectors with the 

appropriate injectors, as supplied (see Table 3).

2.   Unscrew the hex nut from the regulator. The hex nut, brass 

washer and nylon insert will disengage as  

an assembly.

3.   Unclip the nylon insert from the nut assembly by rotating the 

insert ¼ turn, and pulling it free.

4.  Turn over the insert, and clip back into position.
5.   Refit the hex nut assembly to the regulator ensuring that it is fully 

screwed down. The regulator is now set for connection to LP.

6.   Turn on the gas supply and at each new connection check 

for leaks using soapy water: each hotplate valve should be 

turned on, one at a time, and the injector hole blanked off 

for several seconds.

7.   The operation of the regulator can be confirmed by 

connecting a manometer to the pressure test point located 

on the side of the regulator body adjacent to the outlet. 

With the appliance operating check the outlet pressure

  •  when all burners of the appliance are operating  

at maximum,

  •  when the smallest burner of the appliance is operating at 

minimum.

   Under these conditions the outlet pressure should not vary 

from the nominal outlet pressure of 2.60kPa by more than 

+/–0.52kPa.

8.   If the regulator appears to not be performing satisfactorily 

then check the following points.

  •  If the outlet pressure is consistently too low then the inlet 

pressure may be too low and adjustment of an upstream 

regulator may be needed, or an upstream regulator or 

valve with insufficient flow capacity may be present in 

the gas supply line. If this is suspected then it may be 

necessary to repeat the checks whilst measuring both the 

inlet and outlet pressure to determine if the inlet pressure 

is in the range 2.75–7.00kPa.

  •  Check that the insert has been fitted correctly as per 

diagram figure 7. Check that the hex nut is fully  

screwed down.

Summary of Contents for 72K315S

Page 1: ...GAS COOKTOPS User and Installation Manual MODELS GHS607W GHS607S GHC607W GHC607S GHC617W GHC617S GHS917W GHS917S GHC937W GHC937S 72K315W 72K315S GHR12W GHR12S GHR92W GHR92S WHG640WA WHG640SA ...

Page 2: ...e are sure you will find your new appliance a pleasure to use and a great asset to your cooking Before you use the appliance we recommend that you read through the whole user manual which provides a description of the product and its functions To avoid the risks that are always present when you use a cooking appliance it is important that the appliance is installed correctly and that you read the ...

Page 3: ...craft caravans or mobile homes Figure 1 burner cap burner crown ignition electrode injector NOTE You must read these warnings carefully before installing or using the cooktop If you need assistance contact your Customer Care Department The manufacturer will not accept liability should the instructions below or any other safety instructions incorporated in this book be ignored Installation An autho...

Page 4: ...e then try lighting again WARNING caution Burners MUST be operated between HIGH and LOW settings only In the absence of electrical power carry out the ignition directly to the burner with a hand held ignition source Hotplates Choice of hotplate For your convenience there is a choice of hotplates A small burner for special low heat and slow cooking A medium burner for normal cooking and simmering A...

Page 5: ...e sure to follow the polish or brushing lines WARNING caution DO NOT use abraisive scourers or steel wool Trivets burner caps and crowns These can all be lifted off and removed for separate cleaning NOTE When re fitting the burner caps and crowns ensure that they are correctly seated Ensure burners are thoroughly dried after cleaning or spillage When cleaning the burners ensure that all the flame ...

Page 6: ...an and dry Dry or clean ignition electrode Ensure that the crown is seated properly so that the spark fires to the receiving point in the burner crown refer to Figure 1 Ensure injector is clear of foreign material No spark is obtained when control knob is activated Electricity supply is disconnected or switched off Battery is flat Polarity wrong on battery Ignition electrode wet or dirty Switch on...

Page 7: ...s and protection for combustible materials Ensure that the appliance is installed in accordance with clauses 6 2 5 and 6 10 1 1 of AS NZS 5601 1 or clauses 6 9 1 and 6 9 5 of AS NZS 5601 2 with regard to clearances to combustible surfaces and materials and clearances to rangehoods and exhaust fans To ensure clearances of 200mm from burners to vertical combustible surfaces observe the minimum dista...

Page 8: ...dicates the direction of gas flow when the inlet and outlet of the regulator is oriented correctly When the regulator has been fitted check for leaks from the connections with soapy water Gas connection This appliance is supplied for use with Natural Gas However it can be converted for use with LPG Refer to LP conversion on pages 9 11 Supply pipe sizing The total hourly gas consumption for the app...

Page 9: ... to suit LP gas is required The conversion kit contains appropriate LPG injectors and 1 LPG sticker To convert to LPG 1 Remove the hotplate burners to access the hotplate injectors Replace the factory fitted NG injectors with the appropriate injectors as supplied see Table 3 2 Unscrew the hex nut from the regulator The hex nut brass washer and nylon insert will disengage as an assembly 3 Unclip th...

Page 10: ... Turn the knob to maximum and then back to minimum to ensure that the correct minimum flame is maintained 10 Attach the LPG sticker to the cooker near the gas supply inlet Cover the Natural Gas label that is factory fitted BURNER TYPE NATURAL GAS Nominal test point pressure 1 00kPa LPG Nominal test point pressure 2 60kPa Injector size mm Gas consumption MJ h Injector size mm Gas consumption MJ h S...

Page 11: ...s of the appliance are operating at maximum when the smallest burner of the appliance is operating at minimum Under these conditions the outlet pressure should not vary from the nominal outlet pressure of 2 60kPa by more than 0 52kPa 8 If the regulator appears to not be performing satisfactorily then check the following points If the outlet pressure is consistently too low then the inlet pressure ...

Page 12: ...appliance is installed as specified in the local wiring regulations Diagram 1 is a schematic of the wiring in the appliance The weight of the unit is printed on the appliance packaging label Diagram 1 Battery holder installation instructions 1 Locate a convenient position to mount battery holder keeping it away from hot surfaces WARNING warning DO NOT attach it to the base of the cooktop 2 Ensure ...

Page 13: ...d to LPG then the bypass screw will have to be screwed in until a small stable flame results Please ensure the supply pressure has been checked PRIOR to any adjustment 4 If the appliance cannot be adjusted to perform safely inform the customer of the problem and affix an appropriate warning notice to the appliance If the fault appears to be dangerous the appliance should be disconnected If a minor...

Page 14: ...14 NOTES Gas Cooktops notes ...

Page 15: ... supply v incomplete or improper installation vi incorrect improper or inappropriate operation vii insect or vermin infestation viii failure to comply with any additional instructions supplied with the Appliance b the Appliance is modified without authority from Electrolux in writing c the Appliance s serial number or warranty seal has been removed or defaced d the Appliance was serviced or repair...

Page 16: ...r email our Customer Care team or visit our website Australia phone 1300 363 640 fax 1800 350 067 email customercare electrolux com au website www chef com au Chef models www westinghouse com au Westinghouse models New Zealand phone 0800 234 234 fax 0800 363 600 email customercare electrolux co nz website www simpson co nz Simpson models www westinghouse co nz Westinghouse models Top service Top S...

Reviews: