![background image](http://html.mh-extra.com/html/electrolux/72k315s/72k315s_user-manual_21141010.webp)
LPG conversion -
DONG YANG regulator
10 LP CONVERSION - DONG YANG Gas Cooktops
• Check that the regulator has been fitted to the
gas supply line in the correct orientation, the arrow on
the base of the body indicates the direction of gas flow.
Once these checks have been completed, if the regulator
still fails to perform in a satisfactory manner it should be
replaced.
9. One by one, turn the knobs to minimum and screw in the
bypass screw (accessible when the knob is removed – refer
figure 11) until a small stable flame results. Turn the knob
to maximum and then back to minimum to ensure that the
correct minimum flame
is maintained.
10. Attach the LPG sticker to the cooker, near the gas supply
inlet. Cover the Natural Gas label that is
factory fitted.
BURNER TYPE
NATURAL GAS
(Nominal test point pressure: 1.00kPa)
LPG
(Nominal test point pressure: 2.60kPa)
Injector size (mm)
Gas consumption
(MJ/h)
Injector size (mm)
Gas consumption
(MJ/h)
Small burner
1.00
5.1
0.55
4.0
Medium burner
1.35
9.0
0.70
6.5
Large burner
1.60
12.1
0.90
10.7
Wok burner
1.75
14.4
1.00
13.0
Table 3
Insert oriented for natural
gas operation
Insert oriented for LPG
operation
Figure 7
Hex nut
assembly, fully
screwed down
Hex nut assembly,
removed from regulator
and insert disassembled
Summary of Contents for 72K315S