background image

I

NSTALLATION

I

NSTRUCTIONS

D

O W N D R A F T  

V

E N T I L A T I O N

Summary of Contents for DD36I

Page 1: ...INSTALLATION INSTRUCTIONS D O W N D R A F T V E N T I L AT I O N ...

Page 2: ...would like to identify is IMPORTANT NOTE This highlights informa tion that is especially relevant to a problem free installation signals a situation where minor injury or product damage may occur if you do not follow instructions states a hazard that may cause serious injury or death if precautions are not followed WOLF is a registered trademark of Wolf Appliance Company Inc C O N TA C T I N F O R...

Page 3: ...model and serial numbers before installing the downdraft ventilation system Both numbers are listed on the rating plate located above the airbox on the front side of the unit Refer to the illustration below BEFORE YO U S TA RT Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the Wolf Warranty Refer to the Downdraft Ventila...

Page 4: ... A Pro ventilation hood is recommended for use with Wolf dual fuel ranges gas ranges sealed burner range tops and gas rangetops IMPORTANT NOTE A downdraft can be used with sealed burner rangetop Models SRT304 and SRT366 An accessory trim kit SRT DDTRIM is necessary for this installation Contact your Wolf dealer for details Wolf downdraft ventilation systems are available in 30 762 36 914 and 451 2...

Page 5: ...draft must be used with a Wolf approved control module and top cover The remote mounted control module and top cover are available in the classic platinum and carbon stainless steel finish for Models DD30 and DD36 and classic stainless steel only for Model DD45 The control kit available as a sales accessory for Models DD30 and DD36 and included with Model DD45 includes the control module top cover...

Page 6: ...ough space for proper installation 23 8 60 of flat countertop is required behind the cooktop and 13 4 44 is necessary between the back edge of the cooktop and inside of cabinet back If downdraft Model DD30 is installed in combination with with two cooktops or inte grated modules an integrated module support ISUPPORT for downdraft ventilation is required ISUPPORT is not required for Model DD45 If o...

Page 7: ...downdraft assembly and a minimum of 4 102 from the outer edge of cooktop element or burner You will be required to drill three holes and connect the control module to the downdraft assembly using the cable provided The remote mounted control module is 23 8 60 x 65 8 168 and can be positioned horizontally or vertically in the countertop A 1 25 diameter hole for the RJ45 connector cable will be cent...

Page 8: ...Model DD45 in a 451 2 1156 wide cabinet the electrical outlet cannot be located on the back wall of the cabinet The outlet can be placed in an adjacent cabinet within reach of the power cord An access hole for the power cord must be drilled in the cabinet wall Choose the electrical location shown in the illustration below that best suits your installation Do not use an extension cord or two prong ...

Page 9: ...er will minimize the amount of blower noise but will not eliminate the noise completely IMPORTANT NOTE Blower options vary with the cooking surface For recommendations refer to the Wolf Design Guide found on the Wolf website wolfappliance com DISCHARGE CUT OUT DIMENSIONS 101 4 260 x 31 2 89 INTERNAL BLOWER 141 4 362 x 31 2 89 IN LINE OR REMOTE BLOWER CENTERLINE OF COUNTERTOP CUT OUT 163 8 416 INTE...

Page 10: ...ting applications IMPORTANT NOTE Wolf ventilation down draft systems must be vented to the outside Use only metal ductwork Wolf downdraft ventilation systems are designed for use with 31 4 83 x 10 254 ductwork for Models DD30I DD36I and DD45I and 31 4 83 x 14 356 ductwork for Models DD30R DD36R and DD45R Each can be transitioned to 8 203 or 10 254 round ductwork For best performance 10 254 round d...

Page 11: ...low Place the downdraft assembly on its back on a flat work surface Loosen the 4 nuts and 2 clamp channels Slide the blower to the desired position Use the supplied cover plate to close any open space Tighten nuts to secure the top of blower and use sheet metal screws through the bottom flange to secure the bottom of the blower D O W N TO L E F T O R R I G H T D I S C H A R G E Substituting down d...

Page 12: ...he back side of the remote mounted control module Connect the other end of the cable to the electrical connection located on the right side of downdraft assembly Make sure that all connections are tight Refer to the illustration on the front of the downdraft for the correct orientation of the RJ45 connector during installation into the downdraft assembly D O W N D R A F T INSTALLATION C U T T H E ...

Page 13: ...s that hold the blower in place and slide the blower left or right to align with the ductwork Retighten the screws and nuts IMPORTANT NOTE For installations where the ductwork is riveted to the unit a 31 4 83 x 10 254 collar is provided for Models DD30I DD36I and DD45I and a 31 4 83 x 14 356 collar is provided for Models DD30R DD36R and DD45R This will allow the blower to be removed and replaced e...

Page 14: ...nt a standard 120 V AC electrical box with 3 pronged grounded receptacle inside the cabinet or adjacent cabinet Make sure it is located within the reach of the down draft s 21 2 8 m power cord Run the appropriate power cable into the cabinet and connect it to electrical box and outlet The remote blower may not exceed a 6 0 amp rating Run 2 wire plus ground power cable from the remote blower to the...

Page 15: ...e quality built into your down draft ventilation system by calling a Wolf authorized service center For the name and number of the Wolf authorized service center nearest you check the Locator section of our website wolfappliance com or call Wolf Customer Service at 800 332 9513 When calling for service you will need the model and serial number of your down draft This information is found on the pr...

Page 16: ...8 0 8 2 5 6 R E V B 1 1 2 0 0 6 WOLF APPLIANCE COMPANY INC P O BOX 44848 MADISON WI 53744 800 332 9513 WOLFAPPLIANCE COM ...

Reviews: