66
3. Squeeze the tabs on the side of the switch and push
the switch out the front.
Removing the pressure switch assembly:
1. Disconnect the washer from electrical supply.
2. Remove the back panel from the console,
disconnect the wires from the pressure switch and
disconnect the pressure hose.
3. The pressure switch assembly is held to the control
mounting plate by a tab and a screw.
4. Remove the pressure switch knob, remove the
screw and lift the assembly up
.
Removing the electronic moisture sensor control:
1. Disconnect the washer from electrical supply.
2. Remove the back panel from the console and
unplug the harness from the electronic moisture
sensor control.
3. Push up on the top tab to release the control.
Removing the front closure:
1. Disconnect the washer from electrical supply.
2. Remove the back panel from the console.