Spray rinse during the first pump cycle with the temp switch set to:
All settings other than
Timer contact T23 swings from T22 to T24. Terminal T24 provides power through T21 to
the cold water solenoid.
Warm / Warm
Timer contact T23 swings from T22 to T24. Terminal T24 provides power through T21 to
the cold water solenoid and power to terminal C of the temp switch. With contacts FF to
H and FF to C of the temp switch closed, power is applied to the hot solenoid giving a
warm spray rinse.
During the rinse cycle with temp switch set to:
All settings other than
Timer contact T23 swings from T24 to T22 and timer contact T22 is closed to T24. Terminal
T24 provides power through T21 to the cold water solenoid.
Warm / Warm
Timer contact T23 swings from T24 to T22 and timer contact T22 is closed to T24. Terminal
T24 provides power through T21 to the cold water solenoid and power to terminal C of the
temp switch. With contacts FF to H and FF to C of the temp switch closed, power is
applied to the hot solenoid giving a warm rinse.
Warm / Warm
Warm / Warm