2. Remove the mechanism cap by placing a cloth
between pliers jaws and grasping the handle on the
cap. Pull upward firmly until cap pops out.
Reinstalling the mechanism cap:
1. Wipe the mechanism cap o-ring and sealing sur-
face inside the upper agitator with a dry cloth to
remove any foreign material that might prevent a
proper seal. Do not wash out the agitator mecha-
nism or contaminate it with any liquid. Reinstall the
mechanism cap by placing one side of the cap
under the plastic ridge at the level of the upper
agitator softener holes. Push the cap firmly down-
ward. Using a padded instrument such as a rubber
coated pliers handle or a cushioned hammer
handle, work around the cap edge using light
vertical blows until seated. Excessive force may
crack the cap.
Then check the installation by:
a. Making sure the o-ring is properly seated in the
groove on the cap before installation.
b. Looking for the black o-ring through the
softener holes in the upper agitator. The cap
is not properly installed if any black can be
seen.
c. Check that the entire edge of the mechanism
cap is under the four plastic ridges on the
inside of the upper agitator.
Removing the agitator:
1. Raise the top, remove the softener dispenser and
lift the cap out.
2. Using a 1/2 socket remove the bolt from the center
of the agitator shaft and lift the agitator off.
Removing the drive hub:
1. The drive hub is forced on the transmission shaft
by the bolt that holds the agitator to the transmis-
sion shaft.
2. Place a screwdriver between transmission shaft
and the drive hub and force the drive hub off.