32
Installation manual
5.3
Single-phase connection
Demount the cover panel from the supply unit. Connect the earth and other wires as shown.
1NAC
L
N
1NAC
L1
N
1NAC
L1
N
When the installation is completed remount the cover panel and check:
• That the drum is empty.
• That the machine operates by connecting the power to the machine and start a program with heat.