10
Installation manual
2.1.2
Technical data
Weight, net
kg
231
Drum volume
liters
360
Drum diameter
mm
755
Drum depth
mm
831
Drum speed, medium load
rpm
43
Rated capacity, filling factor 1:18 (Max. load)
kg
20
Rated capacity, filling factor 1:22 (Recommended load)
kg
16.4
Heating: Electricity
kW
18.0
Optimum air flow, 18.0 kW**
m
3
/h
580
Optimum static back pressure, 18.0 kW**
Pa
580
Maximum static back pressure, 18.0 kW**
Pa
600
Sound power/pressure level at drying*
dB(A)
72/56
Heat emission of installed power, max
%
15
* Sound power levels measured according to ISO 60704.
** In a cold empty machine.
Connections
Air outlet
⌀
mm
200