14
Installation manual
2.3.2
Technical data
Weight, net
kg
231
Drum volume
liters
360
Drum diameter
mm
755
Drum depth
mm
831
Drum speed, medium load
rpm
43
Rated capacity, filling factor 1:18 (Max. load)
kg
20
Rated capacity, filling factor 1:22 (Recommended load)
kg
16.4
Heating: Gas
kW
21.0
Optimum air flow**
m
3
/h
690
Optimum static back pressure**
Pa
570
Maximum static back pressure**
Pa
600
Sound power/pressure level at drying*
dB(A)
72/56
Heat emission of installed power, max
%
15
* Sound power levels measured according to ISO 60704.
** In a cold empty machine.
Note!
The default gas appliances are built to run on either GNH or LPG gas where shall be installed at not over than
610 m (2001 ft) high altitude otherwise a kit for high altitude must be installed to the machine.
For the kit No. please refer to the spare parts list.
Connections
Air outlet
⌀
mm
200
Gas connection
1/2”
ISO 7/1–R1/2
Summary of Contents for TD6-20LAC
Page 2: ......
Page 51: ......
Page 52: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...