Installation manual
19
7.2.3
Outputs
Connect the power supply (e.g. 24V DC) for the external liquid supplies to 9 and 10. If an internal power supply (from
the machine) is being used, it can be taken from 1 (N) and connected to 9 and from 2 (L) and connected to 10. Max
load on the outputs 0.5 A.
Signals for external liquid supplies 6–10 are connected to 12-16 on the second I/O board type 2:
12 = Signal 6
13 = Signal 7
14 = Signal 8
15 = Signal 9
16 = Signal 10
fig.6236B
6W12
6G01
Signal 6
Detergent Lagoon
-
Signal 7
-
Detergent Main wash
Signal 8
Conditioner Lagoon
-
Signal 9
All in one Lagoon
-
Signal 10
-
Bleach Main wash