Installation manual
21
8 Drain connection
Drain pump
The drainage pipe should be located over a floor drain, drainage channel or the like.
The highest part of the drain hose shall be positioned according to the figure.
Make sure there is no kinks in the hose.
650 mm ± 50 mm /
25 9/16 inch ±
1 15/16 inch
max
100 mm
fig.2029A
9 Electrical connection
9.1
Electrical installation
The electrical installation may only be carried out by qualified personnel.
In accordance with the wiring rules: mount a multi-pole switch prior to the machine to facilitate installation and service
operations.
Connect the machine’s cable to the switch.
Check that the earth has been connected in the correct way.
For the rating of the supply cable, check the local regulations. Min. outer diameter for supply cable ø 10 mm.
The connecting cable shall hang in a gentle curve.
9.2
Electrical connections
Heating alternative
Main voltage
Hz
Heating power
kW
Total power
kW
Recommended fuse
A
Electric heated
220–240V 1N ~
50/60
2.2/2.8
2.4/3.0
16
220–240V 1N ~
50/60
4.4
4.6
20
220-230V 1N ~
50/60
4.4
4.6
25
220–240V 3 ~
50/60
4.4
4.6
16
220–230V 3 ~
50/60
4.4
4.6
20
380–415V 3N ~
50/60
4.4
4.6
10
380-415V 3 ~
50/60
3.6
3.8
10
440V/480 3 ~
50/60
4.0/4.4
4.3/4.7
10
Non heated
100–240V 1/1N ~
50/60
-
0.5
10