7 Connection of external dosing systems
7.1
Connection of the hoses
The machine is prepared for connection of external dosing systems or water re-use systems etc.
EDS, Efficient Dosing System:
• Cut the top of the hose nipples to be used as showed in the figure.
• Connect the hoses to the hose nipples.
Venturi, Efficient Dosing System:
Note!
Connect the hose to the nipple at port (A) only.
• Cut the top of the hose nipple (A) as showed in the figure.
• Connect the hose to the hose nipple (A).
A
fig.X01844
Always connect hoses on connections with a hose clamp.
If the hoses are made of a soft material such as silicon or similar, use a cable tie to fasten the hose on the connection.
If the hoses are made of a hard material, it is not recommended to make the connection tighter by using a cable tie.
Note!
Equipment for external dosing must only be connected to work on pump pressure and not on network
pressure.
7.2
Electrical connection of external dosing system
The power supply to the external dosing system must never be connected to the machine’s incoming terminal
block or to the edge connectors on the I/O-board.