![Electrolux Professional A7FTEDCSI0 Service Manual Download Page 69](http://html.mh-extra.com/html/electrolux-professional/a7ftedcsi0/a7ftedcsi0_service-manual_2385587069.webp)
69
FRY TOP 700/900 EL/GAS
6.3.3.2 THERMOSTAT
&
SAFETY
THERMOSTAT
BULB
-
700
&
900
Depending on the size (400/800 etc) of an appliance there can be several temperature/safety temp. bulb
probes.
Every 400mm (half of a module), there will be a temperature bulb and a safety temperature bulb.
NOTE!
The thermostat and the safety thermostat bulbs are not inserted in the same groove and are not
inserted at the same depth!!, this is important for the correct temperature detection. The depth of
the grooves can be different so the two bulbs cannot be exchanged of position!!!.
Summary of Contents for A7FTEDCSI0
Page 16: ...16 FRY TOP 700 900 EL GAS GAS APPLIANCES 700 x 400mm 700 x 800mm 900 x 400mm 900 x 800mm ...
Page 39: ...39 FRY TOP 700 900 EL GAS ELECTRIC SYSTEM 700 900 ...
Page 66: ...66 FRY TOP 700 900 EL GAS 6 3 2 5 BURNER 700 900 6 3 2 6 SAFETY THERMOSTAT 700 900 ...
Page 68: ...68 FRY TOP 700 900 EL GAS 6 3 3 1 SELECTOR AND TERMOSTAT 700 900 ...
Page 70: ...70 FRY TOP 700 900 EL GAS 6 3 3 3 HEATING ELEMENT 700 900 700 900 ...
Page 71: ...71 FRY TOP 700 900 EL GAS 6 3 3 4 SAFETY THERMOSTAT 700 900 ...