FRY TOP 700/900 EL/GAS
FUNCTIONNG OF THE INTERRUPTED TC AND SAFETY THERMOSTAT
When the pilot is lit and the TC is producing sufficient millivolts to keep engaged the flame failure magnetic coil
of the valve ; approx 8/10 MilliVolt produced from TC / Magnetic coil requires approx 1,5MilliVolt to keep en-
gaged.
When the system is in function: gas will flow freely to the burner and the working cycle will be lead by the work
thermostat set point.
The only way to shut down the system is to disengage the magnetic coil of the valve, this can happen if the
safety temperature thermostat will trip, or in case that the TC will not generate sufficient millivolts (flame of pilot
shut down).
The TC is called interrupted because its wiring/voltage is not going directly from the pilot to the valve, if first
will flow through the safety thermostat that in case of need can cut out the circuit.