![Electrolux Professional A7FTEDCSI0 Service Manual Download Page 41](http://html.mh-extra.com/html/electrolux-professional/a7ftedcsi0/a7ftedcsi0_service-manual_2385587041.webp)
41
FRY TOP 700/900 EL/GAS
4.2.1.1 GAS
VALVE
700
The 700 appliances have a different valve than the 900. These appliances are equipped with a specific ther-
mostatic valve (EUROSIT). The tech features of this valve are specially manufactured for Electrolux.
Note that: the igniter is external to the valve, on the control panel you will find a piezo igniter (external compo-
nent).
IMPORTANT!
NO NOZZLE REPLACEMENT, PRESSURE OUTLET ADJUSTMENTS ARE REQUIRED!
PRESSURE CHECK
:
The nominal valve inlet pressure check must be
measured while the appliance operates, using a
manometer (min 0,1 mbar).
The access “6” is the inlet pressure to the valve.
Remove the screw “ 6 ”; connect a monometer “ O
“; compare the value read on the manometer to the
value to the data given in the tech specs tables
(Refer to §
TECHNICAL CHARACTERISTICS
).
Fit back the access point screw “ 6 ”after finishing
the checking.
T
he access “7” is the outlet pressure to the burner.
NO VALVE ADJUSTMENTS ARE REQUIRED.
CAUTION!
If the manometer “O”gives a reading out-
side the range value indicated in the tech
specs (high pressure or low pressure),
do not terminate the commissioning of
the appliance and inform the cus-
tomer/gas company.
PILOT BURNER ADJUSTMENT (gas flow)
:
The pilot can be adjusted if necessary; the adjust-
ment of the pilot flame is obtained and set in the
factory, however, in case of need: turn the screw
“
5
“ clockwise to reduce the pilot gas flow, counter-
clockwise to increase.
Summary of Contents for A7FTEDCSI0
Page 16: ...16 FRY TOP 700 900 EL GAS GAS APPLIANCES 700 x 400mm 700 x 800mm 900 x 400mm 900 x 800mm ...
Page 39: ...39 FRY TOP 700 900 EL GAS ELECTRIC SYSTEM 700 900 ...
Page 66: ...66 FRY TOP 700 900 EL GAS 6 3 2 5 BURNER 700 900 6 3 2 6 SAFETY THERMOSTAT 700 900 ...
Page 68: ...68 FRY TOP 700 900 EL GAS 6 3 3 1 SELECTOR AND TERMOSTAT 700 900 ...
Page 70: ...70 FRY TOP 700 900 EL GAS 6 3 3 3 HEATING ELEMENT 700 900 700 900 ...