FUNCTIONING OF THE FLAME FAILURE DEVICE / MAGNETIC VALVE COIL
STAGE 1:
Appliance is gas supplied, pilot turned off.
STAGE 2:
Press the knob, strike the igniter, once that the TC has engaged onto the magnetic coil the valve
will remain open but not gas will flow towards the burner.
STAGE 3:
when TC is engaged, coil open, if the knob is released the gas flow can go towards the burner.