FRY TOP 700/900 EL/GAS
4.2.1.2 GAS
VALVE
900
The 900 appliances have a different valve than the 700.
The manual thermostatic gas valve (MERTIK), is fixed on both sides with a screw, the pipes can be loosened
with a wrench while the thermostat capillary and electronic ignition cable need to be loosened from their hous-
ing.
NOTE!
The valve features a thermal re-light locking device enabled until the thermocouple is hot. Such device,
called interlock, keeps engaged for about 40 seconds in case of accidental pilot flame shut off, hence
allowing accumulated gas to flow out through the chimney prior to light any spark again. During this pe-
riod of time, if the device is active the know will not turn!.
Forcing the interlock leads to a valve damage which is not covered by the original . .
Fix
screw
Fix
screw
Pilot gas
pipe
Thermocouple
Gas inlet sup-
ply pipe
Burner
supply
pipe
Electronic ig-
nition cable
Thermostat
capillary
Minimum screw - Modu-
lating or ON/OFF function
The magnetic coil is
part of the valve; it
can be accessed by
loosening the re-
taining nut of the
TC
Retain-
ing nut
Summary of Contents for A7FTEDCSI0
Page 16: ...16 FRY TOP 700 900 EL GAS GAS APPLIANCES 700 x 400mm 700 x 800mm 900 x 400mm 900 x 800mm ...
Page 39: ...39 FRY TOP 700 900 EL GAS ELECTRIC SYSTEM 700 900 ...
Page 66: ...66 FRY TOP 700 900 EL GAS 6 3 2 5 BURNER 700 900 6 3 2 6 SAFETY THERMOSTAT 700 900 ...
Page 68: ...68 FRY TOP 700 900 EL GAS 6 3 3 1 SELECTOR AND TERMOSTAT 700 900 ...
Page 70: ...70 FRY TOP 700 900 EL GAS 6 3 3 3 HEATING ELEMENT 700 900 700 900 ...
Page 71: ...71 FRY TOP 700 900 EL GAS 6 3 3 4 SAFETY THERMOSTAT 700 900 ...