Part Numbering System
The sample below is the part number for a 20 ft. sensor with ¼ inch resolution, one temperature
sensor, and a single float going into a tank with a 4-inch port and being wired up as two-wire RS485.
Figure 6 - RU Flex 2100 DLS Part Numbering System
In addition to the information provided within the part number, other information is necessary
when ordering:
1.
Total Tube Length: Default is Measurement Length plus 18 inches.
Note: If installing in a dome-top tank, like a fiberglass tank, sensor will need to be
ordered 1’ longer than the tank height to accommodate the extra height the dome
adds.
2.
Baud Rate and Parity Desired: Default is 9600, N, 8, 1. If other baud rate and parity are
required, please specify.
3.
Unit Numbers Required: If ordering more than one sensor for a location you may have
the level sensors pre-addressed with the required unit numbers prior to shipment for
the tanks on that location. Example: If there are 3 tanks on one location, then specify
that the level sensors be addressed U01, U02, and, U03. Alternate numbering sequences
may be chosen. If no unit numbers are specified, then default will be Unit 01.