© 2020, Electrolab, Inc.
March 2020
Table 2. Holding Registers
Sensor Data
Register
Address
No. Reg.
Values
Type
Float 1 (Top
Float)
43991
3990
1
Read Only
Total Fluid Level in
Tank
16 bit Unsigned
integer or 32 bit
floating point
Float 2
(Bottom
Float)
43992
3991
1
Read Only
Water Interface
Level in Tank
16 bit Unsigned
integer or 32 bit
floating point
Oil Level in
Tank (top to
bottom)
43993
3992
1
Read Only
Oil Level in Tank
(top-bottom)
16 bit Unsigned
integer or 32 bit
floating point
Total Volume
(top level x
K_factor)
43994
3993
1
Read Only
Total Volume (top
level x K factor)
16 bit Unsigned
integer or 32 bit
floating point
Oil Volume
(top level –
bottom level)
x K_factor
43995
3994
1
Read Only
Oil Volume
16 bit Unsigned
integer or 32 bit
floating point
Water
Volume
(bottom level
x K_factor)
43996
3995
1
Read Only
Water Volume
16 bit Unsigned
integer or 32 bit
floating point
Temperature1
43997
3996
1
Read Only
Temperature1
16 bit Unsigned
integer or 32 bit
floating point
Temperature2
43998
3997
1
Read Only
Temperature2
16 bit Unsigned
integer or 32 bit
floating point
Temperature3
43999
3998
1
Read Only
Temperature3
16 bit Unsigned
integer or 32 bit
floating point
Temperature4
44000
3999
1
Read Only
Temperature4
16 bit Unsigned
integer or 32 bit
floating point
Temperature5
44001
4000
1
Read Only
Temperature5
16 bit Unsigned